CLIA Kit for Cystatin 3 (CST3)Homo sapiens (Human)Sandwich CLIA

Cys-C; Cystatin C; Gamma Trace; Post-Gamma-Globulin; Neuroendocrine Basic Polypeptide; Amyloid Angiopathy And Cerebral Hemorrhage

  • Product No.SCA896Hu
  • Organism SpeciesHomo sapiens (Human)Same name, Different species.
  • Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
  • Test MethodDouble-antibody Sandwich
  • Assay Length2h, 40min
  • Detection Range0.78-200ng/mL
  • SensitivityThe minimum detectable dose of this kit is typically less than 0.12ng/mL.
  • Specificity This assay has high sensitivity and excellent specificity for detection of Cystatin 3 (CST3).
    No significant cross-reactivity or interference between Cystatin 3 (CST3) and analogues was observed.
  • ApplicationsChemiluminescent immunoassay for Antigen Detection
  • DownloadInstruction Manual
  • Format48T96T96T*596T*1096T*100
  • FOBUS$ 588US$ 840US$ 3780US$ 7140US$ 58800
  • CLIA Kit for Cystatin 3 (CST3)Package and Components
  • CLIA Kit for Cystatin 3 (CST3)Package and Components
  • CLIA Kit for Cystatin 3 (CST3)Results demonstration
  • SCA896Hu.jpgTypical Standard Curve
  • CertificateISO9001: 2008, ISO13485: 2003 Registered


Matrices listed below were spiked with certain level of recombinant Cystatin 3 (CST3) and the recovery rates were calculated by comparing the measured value to the expected amount of Cystatin 3 (CST3) in samples.

MatrixRecovery range (%)Average(%)
EDTA plasma(n=5)96-105101
heparin plasma(n=5)99-105102


Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cystatin 3 (CST3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cystatin 3 (CST3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%


The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cystatin 3 (CST3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

EDTA plasma(n=5)88-101%78-95%80-96%80-101%
heparin plasma(n=5)78-91%81-105%92-103%90-99%


The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
Substrate A1×10mLSubstrate B1×2mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

CLIA Kit for Cystatin 3 (CST3)

Test principle

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated secondary antibody. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Cystatin 3 (CST3) level in the sample or standard.