Home  |   About us
ITEM PROTEIN ANTIBODY ASSAY KIT CELL
CLIA Kit for Lysosomal Associated Membrane Protein 2 (LAMP2)
CD107-B; LAMP-2C; LAMPB; LGP96; CD107b
Organism species Mus musculus (Mouse)
Product No.SCB464Mu
Sample typeSerum, plasma and other biological fluids
Format96-well strip plate
Assay length4.5 hours
Detection range0.055-40ng/mL The standard curve concentrations used for the ELISA’s were 40ng/mL, 13.33ng/mL, 4.44ng/mL, 1.48ng/mL, 0.494ng/mL, 0.165ng/mL, 0.055ng/mL
SensitivityThe minimum detectable dose of this kit is typically less than 0.207ng/mL.
Specificity
This assay has high sensitivity and excellent specificity for detection of Lysosomal Associated Membrane Protein 2 (LAMP2).
No significant cross-reactivity or interference between Lysosomal Associated Membrane Protein 2 (LAMP2) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Lysosomal Associated Membrane Protein 2 (LAMP2) and the recovery rates were calculated by comparing the measured value to the expected amount of Lysosomal Associated Membrane Protein 2 (LAMP2) in samples.
Matrix Recovery range (%) Average(%)
serum(n=5)80-10599
EDTA plasma(n=5)90-9793
heparin plasma(n=5)80-9087
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lysosomal Associated Membrane Protein 2 (LAMP2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lysosomal Associated Membrane Protein 2 (LAMP2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lysosomal Associated Membrane Protein 2 (LAMP2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5)79-89%94-104%80-93%79-101%
EDTA plasma(n=5)82-96%93-101%90-104%89-104%
heparin plasma(n=5)84-98%98-105%86-101%81-91%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1
Test principle
The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated secondary antibody. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Lysosomal Associated Membrane Protein 2 (LAMP2) level in the sample or standard.
Package and Components
Assay procedure summary
1. Prepare all reagents, samples and     standards;
2. Add 100µL standard or sample to each     well. Incubate 2 hours at 37oC;
3. Aspirate and add 100µL prepared     Detection Reagent A. Incubate 1 hour at     37oC;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate     10 minutes at 37oC;
8. Read RLU value immediately.
Reagent Preparation
Results demonstration
Download
Benchmark price
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications
PAB464Mu01Polyclonal Antibody to Lysosomal Associated Membrane Protein 2 (LAMP2)WB, ICC, IHC-P, IHC-F, ELISA
RPB464Mu01Recombinant Lysosomal Associated Membrane Protein 2 (LAMP2)SDS-PAGE; WB; ELISA; IP.
SCB464MuCLIA Kit for Lysosomal Associated Membrane Protein 2 (LAMP2)Chemiluminescent immunoassay