ELISA Kit for Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2)

CPTASE; Carnitine O-Palmitoyltransferase 2; Carnitine palmitoyltransferase II
Typical Standard Curve Typical Standard Curve

Sample type Tissue homogenates and other biological fluids. Detection range 0.313-20ng/mL The standard curve concentrations used for the ELISA's were 20ng/mL, 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.313ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.117ng/mL. Specificity This assay has high sensitivity and excellent specificity for detection of Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2).
No significant cross-reactivity or interference between Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2) and analogues was observed.

Precision Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test principle The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Carnitine Palmitoyltransferase 2, Mitochondrial (CPT2) in the samples is then determined by comparing the O.D. of the samples to the standard curve. Assay procedure summary 1. Prepare all reagents, samples and standards;
Reagent Preparation
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Reference
  • Journal of the Neurological SciencesRead more(ScienceDirect: S0022510X14000975)Normal protein content but abnormally inhibited enzyme activity in muscle carnitine palmitoyltransferase II deficiency
  • J Neurol Sci. Read more(Pubmed:24602495)Normal protein content but abnormally inhibited enzyme activity in muscle carnitine palmitoyltransferase II deficiency
Reagents and materials provided
  • Pre-coated, ready to use 96-well strip plate1
  • Plate sealer for 96 wells4
  • Standard2
  • Standard Diluent1×20mL
  • Detection Reagent A1×120µL
  • Assay Diluent A1×12mL
  • Detection Reagent B1×120µL
  • Assay Diluent B1×12mL
  • TMB Substrate1×9mL
  • Stop Solution1×6mL
  • Wash Buffer (30 × concentrate)1×20mL
Leave your messages here

Welcome to our website. If you have any questions, please send a message to us.
We'll Feedback to you within 24 hours.Our work time is from AM 8:00 to PM 4:30 (U.S. Central Time)

  • Sales:sales@cloud-clone.us
  • After-sales:service@cloud-clone.us
  • Email:mail@cloud-clone.us
  • Close