• Promotion products
ELISA Kit for Complement 1q (C1q) Homo sapiens (Human) Sandwich ELISA

C1-q

  • Product No.SEA747Hu
  • Organism SpeciesHomo sapiens (Human) Same name, Different species.
  • Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
  • Test MethodDouble-antibody Sandwich
  • Assay Length3h
  • Detection Range0.312-20ng/mL
  • SensitivityThe minimum detectable dose of this kit is typically less than 0.137ng/mL.
  • Specificity This assay has high sensitivity and excellent specificity for detection of Complement 1q (C1q).No significant cross-reactivity or interference between Complement 1q (C1q) and analogues was observed.
  • ApplicationsEnzyme-linked immunosorbent assay for Antigen Detection.
  • DownloadInstruction Manual
  • UOM 48T96T 96T*5 96T*10 96T*100 Ensure in stock; if not, free redo!
  • FOB US$ 280.00 US$ 400.00 US$ 1,800.00 US$ 3,400.00 US$ 28,000.00
  • Quantity
  • Add to Cart Distributors
  • ELISA Kit for Complement 1q (C1q) Packages (Simulation)
  • ELISA Kit for Complement 1q (C1q) Packages (Simulation)
  • ELISA Kit for Complement 1q (C1q) Results demonstration
  • SEA747Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Complement 1q (C1q) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement 1q (C1q) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 79-91 82
heparin plasma(n=5) 95-103 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement 1q (C1q) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement 1q (C1q) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement 1q (C1q) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 88-96% 89-99% 80-102%
EDTA plasma(n=5) 80-90% 92-105% 84-102% 78-91%
heparin plasma(n=5) 94-101% 80-91% 84-93% 91-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

ELISA Kit for Complement 1q (C1q)

Test principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement 1q (C1q). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement 1q (C1q). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement 1q (C1q), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement 1q (C1q) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Reference

  • Journal of Clinical Immunology Complement activation contributes to the injury and outcome of kidney in human anti-glomerular basement membrane disease.PubMed: 22941511
  • Fish and Shellfish ImmunologyCharacterization of complement 1q binding protein of tiger shrimp, Penaeus monodon, and its C1q binding activityPubmed: 23085472
  • Journal of NeuroimmunologyAcute and prolonged complement activation in the central nervous system during herpes simplex encephalitisPubmed:27235358

Recommend products