Multiplex Assay Kit for Vimentin (VIM) ,etc. by FLIA (Flow Luminescence Immunoassay) Bos taurus; Bovine (Cattle) Multiplex ELISA

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Vimentin (VIM) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Vimentin (VIM) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Vimentin (VIM) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMB040Bo.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Vimentin (VIM) and the recovery rates were calculated by comparing the measured value to the expected amount of Vimentin (VIM) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-105 98
EDTA plasma(n=5) 89-97 92
heparin plasma(n=5) 87-101 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vimentin (VIM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vimentin (VIM) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vimentin (VIM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 86-104% 97-105% 90-98%
EDTA plasma(n=5) 88-102% 78-98% 83-97% 90-104%
heparin plasma(n=5) 83-101% 91-105% 79-96% 79-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:VIM) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Vimentin (VIM) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Vimentin (VIM) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Vimentin (VIM) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Vimentin (VIM) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Vimentin (VIM) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

Giveaways

Citations

  • Aberrant Vimentin Methylation Is Characteristic of Breast Cancerpubmed:22315367
  • Glyoxalase 1-knockdown in human aortic endothelial cells - effect on the proteome andendothelial function estimates.pubmed:27898103
  • HtrA3 is a cellular partner of cytoskeleton proteins and TCP1α chaperoninPubmed:29477555
  • Growth hormone induces Notch1 signaling in podocytes and contributes to proteinuria in diabetic nephropathyPubmed: 31511328
  • Extracellular vesicles derived from injured vascular tissue promote the formation of tertiary lymphoid structures in vascular allograftsPubmed: 31729155
  • Is Vimentin the Cause or Effect of Obstructive Sleep Apnea Development?Pubmed: 32088750
  • ZNF471 modulates EMT and functions as methylation regulated tumor suppressor with diagnostic and prognostic significance in cervical cancer33566221
  • Metastatic suppression by DOC2B is mediated by inhibition of epithelial-mesenchymal transition and induction of senescence33758996
  • Comparison of Vimentin Levels Between Preeclamptic and Normotensive Pregnant Women
  • Advanced glycation end-products associate with podocytopathy in type II diabetic patients
  • Non-POU Domain-Containing Octamer-Binding (NONO) Protein Stability Regulated by PIN1 is Crucial for Breast Cancer Tumorigenicity Via the MAPK/β …

Recommend products