Multiplex Assay Kit for Adenosine Deaminase (ADA) ,etc. by FLIA (Flow Luminescence Immunoassay) Rattus norvegicus (Rat) Multiplex ELISA

Adenosine Aminohydrolase

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Adenosine Deaminase (ADA) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Adenosine Deaminase (ADA) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Adenosine Deaminase (ADA) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMB390Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Adenosine Deaminase (ADA) and the recovery rates were calculated by comparing the measured value to the expected amount of Adenosine Deaminase (ADA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-92 80
EDTA plasma(n=5) 85-103 92
heparin plasma(n=5) 85-98 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adenosine Deaminase (ADA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adenosine Deaminase (ADA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adenosine Deaminase (ADA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-98% 81-90% 91-105% 87-101%
EDTA plasma(n=5) 87-94% 83-91% 80-101% 86-96%
heparin plasma(n=5) 81-104% 78-101% 85-93% 88-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ADA) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Adenosine Deaminase (ADA) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Adenosine Deaminase (ADA) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Adenosine Deaminase (ADA) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Adenosine Deaminase (ADA) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Adenosine Deaminase (ADA) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

Giveaways

Citations

  • Serum adenosine deaminase activity in Iraqi patients with breast cancer on tamoxifen therapyScopeMed: source
  • Purine metabolism and oxidative stress in children with autistic spectrum disorders.Scopemed: Source
  • Caspase-3, Bcl-2, p53, CYP1A1 and COX -2 as a potential target in chemoprevention of Benzo (a) pyrene-induced lung carcinogenesis in mice: Role of thymoquinoneportal:uploads
  • Chemopreventive Role of Curcumin in benzo(A)pyrene induced Lung Carcinogenesis in mice via-modulation of Bcl-2, p53, Caspase-3, Cyp1A1, COX-2 and antioxidant defense system in Lung tissuesportal:uploads
  • Elevated serum adenosine deaminase levels in neuroleptic-naive patients with recent-onset schizophreniaS1876201816303677
  • Elevated serum adenosine deaminase levels in neuroleptic-na¨ıve patients with recent-onset schizophreniapubmed:29061410

Recommend products