Multiplex Assay Kit for Angiotensin 1-7 (Ang1-7) ,etc. by FLIA (Flow Luminescence Immunoassay)
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 462.00 US$ 480.00 US$ 506.00 US$ 542.00 US$ 577.00 US$ 630.00 US$ 710.00 US$ 888.00
- Quantity
Overview
Properties
- Product No.LMS085Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- Category
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Angiotensin 1-7 (Ang1-7) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin 1-7 (Ang1-7) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-102 | 98 |
EDTA plasma(n=5) | 84-99 | 93 |
heparin plasma(n=5) | 92-101 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin 1-7 (Ang1-7) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin 1-7 (Ang1-7) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin 1-7 (Ang1-7) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 86-94% | 93-101% | 84-101% | 80-89% |
EDTA plasma(n=5) | 78-99% | 88-99% | 88-102% | 93-102% |
heparin plasma(n=5) | 82-94% | 85-96% | 94-104% | 92-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:Ang1-7) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.
Giveaways
Increment services
Citations
- Improvement of Plasma Biomarkers after Switching Stroke Patients from Other Angiotensin II Type I Receptor Blockers to OlmesartanPubMed: 25891757
- Angiotensin-(1-7) in Paraventricular Nucleus Contributes to the Enhanced Cardiac Sympathetic Afferent Reflex and Sympathetic Activity in Chronic Heart Failure Ratspubmed:28848201
- Hydrogen Sulfide Attenuates Atherosclerosis in a Partially Ligated Carotid Artery Mouse model via Regulating Angiotensin Converting Enzyme 2 Expressionpubmed:29066981
- The ACE2-Ang (1-7)-Mas receptor axis attenuates cardiac remodeling and fibrosis in post-myocardial infarction.pubmed:28656296
- Relationship between genetic variants of ACE2 gene and circulating levels of ACE2 and its metabolites.pubmed:28895159
- Effects of IQP, VEP and Spirulina platensis hydrolysates on the local kidney renin angiotensin system in spontaneously hypertensive ratspubmed:28944898
- A Study of the Correlation between Angiotensin (1-7) and the Histopathological Changes in the Penises of Experimentally Diabetic Rats2-1980272_83198.htm
- Mesenchymal stem cell–derived microvesicles alleviate pulmonary arterial hypertension by regulating renin-angiotensin systemPubmed:29752040
- Lipoxin A attenuates LPS-induced acute lung injury via activation of the ACE2-Ang-(1-7)-Mas axisPubmed:29969931
- Acute Biochemical, Cardiovascular, and Autonomic Response to Hyperbaric (4 atm) Exposure in Healthy SubjectsPubmed:29977313
- The impact of ovulation inducing drugs on carcinogenesis
- Changes of angiotensin II (1–8) and angiotensin (1–7) levels in early and late-onset preeclampsia
- Therapeutic Delivery of Ang (1-7) Via Genetically Modified Probiotic: A Dosing Study.Pubmed: 31586210
- Significance of the angiotensin I/angiotensin II/angiotensin‐(1‐7) axis in the pathogenesis of systemic sclerosisPubmed: 31746507
- Alteration and association between serum ACE2/angiotensin (1-7)/Mas axis and oxidative stress in chronic kidney disease: A pilot studyPubmed: 32756181
- Dikkat Eksikliği Hiperaktivite Bozukluğu Tanısı Olan Anjiyotensin I, II, III, Alamandin peptid, Anjiyotensin Dönüştürücü Enzim (ACE), NADPH Oksidaz Enzim Serum …
- Angiotensin-(1¨C7) attenuates collagen-induced arthritis via inhibiting oxidative stress in rats33398523
- The prevalence and role of functional autoantibodies to angiotensin-converting-enzyme-2 in patients with systemic sclerosis33910447
- Ang-(1-7) Protects Skeletal Muscle Function in Aged Mice
- Angiotensin-(1-7) protects against sepsis-associated left ventricular dysfunction induced by lipopolysaccharide34298021
- Ang-(1–7) protects skeletal muscle function in aged mice34548056
- Resveratrol Confers Protection Against Ischemia/Reperfusion Injury by Increase of Angiotensin (1-7) Expression in a Rat Model of Myocardial Hypertrophy34232225