Multiplex Assay Kit for Annexin A1 (ANXA1) ,etc. by FLIA (Flow Luminescence Immunoassay)
ANX-A1; ANX1; LPC1; Lipocortin I; Chromobindin-9; Calpactin II; Phospholipase A2 inhibitory protein
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 437.00 US$ 454.00 US$ 479.00 US$ 512.00 US$ 546.00 US$ 596.00 US$ 672.00 US$ 840.00
- Quantity
Overview
Properties
- Product No.LME787Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryTumor immunity
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Annexin A1 (ANXA1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Annexin A1 (ANXA1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-88 | 82 |
EDTA plasma(n=5) | 78-99 | 80 |
heparin plasma(n=5) | 79-99 | 92 |
sodium citrate plasma(n=5) | 96-105 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Annexin A1 (ANXA1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Annexin A1 (ANXA1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Annexin A1 (ANXA1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-101% | 79-101% | 90-97% | 79-96% |
EDTA plasma(n=5) | 87-96% | 89-103% | 80-89% | 89-104% |
heparin plasma(n=5) | 83-97% | 89-103% | 80-101% | 80-90% |
sodium citrate plasma(n=5) | 90-101% | 94-104% | 89-98% | 83-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:ANXA1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.
Giveaways
Increment services
Citations
- Dysregulation of Anti-Inflammatory Annexin A1 Expression in Progressive Crohns DiseasePubMed: PMC3794972
- Modulatory Effect of Phytoestrogens and Curcumin on Induction of Annexin 1 in Human Peripheral Blood Mononuclear Cells and their Inhibitory Effect on Secretory Phospholipase A2Ajol: Source
- Host Biomarkers of Invasive Pulmonary Aspergillosis to Monitor Therapeutic ResponseAsm: Source
- Characterization of secretomes from a human blood brain barrier endothelial cells in-vitro model after ischemia by stable isotope labeling with aminoacids in cell culture (SILAC)PubMed: 26718731
- Annexin A1 Is a Key Modulator of Mesenchymal Stromal Cell–Mediated Improvements in Islet FunctionPubMed: 26470781
- Annexin A1 Is Increased in the Plasma of Preeclamptic WomenPubMed: 26398190
- 膜联蛋白A1 和CA19-9 在胆管癌中的表达及其临床意义article:8686
- Protective Aptitude of Annexin A1 in Arterial Neointima Formation in Atherosclerosis-Prone Mice-Brief Report.pubmed:28062503
- Mesenchymal stromal cells improve human islet function through released products and extracellular matrix.pubmed:29101297
- Proresolving protein Annexin A1: The role in type 2 diabetes mellitus and obesityPubmed:29677533
- Annexin A1 is elevated in patients with COPD and affects lung fibroblast functionPubmed:29440885
- Applying host disease status biomarkers to therapeutic response monitoring in invasive aspergillosis patientsPubmed:29370415
- EFFECTS OF MULTICOMPONENT EXERCISE ON PROGRESSION OF BRAIN ATROPHY AND COGNITION IN AMNESTIC MILD COGNITIVE IMPAIRMENT …pdf:3395
- Resolution of inflammation in neuromyelitis optica spectrum disordersPubmed: 30300851
- Effects of annexin A1 on apoptosis and cell cycle arrest in human leukemic cell lines
- Annexin A1 accounts for an anti-inflammatory binding target of sesamin metabolitesPubmed: 32133417
- ANXA1 directs Schwann cells proliferation and migration to accelerate nerve regeneration through the FPR2/AMPK pathwayPubmed: 32908567
- Expression of annexin-A1 in blood and tissue leukocytes of leprosy patients33263684
- Annexin-A1 SUMOylation regulates microglial polarization after cerebral ischemia by modulating IKK¦Á stability via selective autophagy33523920