Multiplex Assay Kit for Beclin 1 (BECN1) ,etc. by FLIA (Flow Luminescence Immunoassay)
ATG6; VPS30; Coiled-Coil,Myosin-Like BCL2 Interacting Protein; ATG6 Autophagy Related 6 Homolog
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 474.00 US$ 492.00 US$ 520.00 US$ 556.00 US$ 593.00 US$ 648.00 US$ 730.00 US$ 912.00
- Quantity
Overview
Properties
- Product No.LMJ557Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryInfection immunity
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Beclin 1 (BECN1) and the recovery rates were calculated by comparing the measured value to the expected amount of Beclin 1 (BECN1) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 96-103 | 101 |
| EDTA plasma(n=5) | 80-94 | 88 |
| heparin plasma(n=5) | 90-101 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beclin 1 (BECN1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beclin 1 (BECN1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Beclin 1 (BECN1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 94-102% | 94-105% | 84-99% | 78-94% |
| EDTA plasma(n=5) | 94-101% | 96-103% | 95-103% | 81-99% |
| heparin plasma(n=5) | 88-102% | 89-98% | 85-94% | 80-96% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:BECN1) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Beclin 1 (BECN1) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Beclin 1 (BECN1) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Beclin 1 (BECN1) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Beclin 1 (BECN1) in the sample and corresponding value of MFI (Median Fluorescence Intensity).
Giveaways
Increment services
Citations
- Can Enhanced Autophagy be Associated with Human Longevity? Serum Levels of the Autophagy Biomarker Beclin-1 are Increased in Healthy CentenariansPubmed:25307612
- A peel-off facial mask comprising myoinositol and trehalose-loaded liposomes improves adult female acne by reducing local hyperandrogenism and activating autophagypubmed:28342238
- The novel CXCR4 antagonist, PRX177561, reduces tumor cell proliferation and accelerates cancer stem cell differentiation in glioblastoma preclinical modelspubmed:28639900
- Beclin1 circulating levels and accelerated ageing markers in COPD DOI: 10.1183/1393003.congress-2017.PA1018
- Beclin1 circulating levels and accelerated aging markers in COPDPubmed:29402890
- A novel combined score of biomarkers in sputum may be an indicator for lung cancer: A pilot studyDoi: 10.1016/j.cca.2018.09.027
- Serum concentration of autophagy-related protein 7 is correlated with non-alcoholic fatty liver disease in Chinese adults
- Crosstalk between vitamin D axis, inflammation and host immunity mechanisms: A prospective study33936265
- Inhibition of HepG-2 Cells (Liver Cancer Cell Line) Viability by 3-Hydroxypyridine-2-Carboxaldehyde N (4)-Methylthiosemicarbazone
- BIOMARKERS OF AUTOPHAGY AND ANTIVIRAL ROLE OF PLACENTA FOR PREDICTING PRETERM DELIVERY IN PATIENTS WITH PRETERM DELIVERY?¡
- IDENTIFICATION OF FACTORS CONNECTED WITH AUTOPHAGY ACTIVITY UNDER CONDITIONS OF PARTIAL NUTRITIONAL DEPRIVATION IN MEN