Multiplex Assay Kit for Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay)
b-EP
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 472.00 US$ 490.00 US$ 517.00 US$ 553.00 US$ 590.00 US$ 644.00 US$ 726.00 US$ 907.00
- Quantity
Overview
Properties
- Product No.LMA806Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategorySignal transductionEndocrinologyNeuro scienceHormone metabolism
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-102 | 81 |
EDTA plasma(n=5) | 88-95 | 91 |
heparin plasma(n=5) | 89-103 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Beta-Endorphin (bEP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 98-105% | 85-93% | 85-99% | 79-101% |
EDTA plasma(n=5) | 82-93% | 79-99% | 94-102% | 93-104% |
heparin plasma(n=5) | 97-105% | 78-96% | 80-89% | 93-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:bEP) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.
Giveaways
Increment services
Citations
- Endogenous μ-opioid peptides modulate immune response towards malignant melanomaPublish: RD10279
- Physiology and cell biology of acupuncture observed in calcium signaling activated by acoustic shear wave SpringerLink: tv015l3126833315
- Effect of Ramadan fasting on endorphin and endocannabinoid level in serum, PBMC and macrophageIjpsi: Source
- Evaluation of immune parameters in chronic migraine with medication overusePubmed:24867859
- Cerebrospinal fluid and plasma b-endorphin levels in children with cerebral malaria.pubmed:28413714
- Ultraviolet A photosensitivity profile of dexchlorpheniramine maleate and promethazine-based creams: Anti-inflammatory,antihistaminic, and skin barrier protection propertiesDOI: 10.1111/jocd.12349
- Non‐pharmacological interventions during childbirth for pain relief, anxiety, and neuroendocrine stress parameters: A randomized controlled trialPubmed:29512230
- КОРРЕКЦИЯ ЦИТОКИНОВОГО И ГОРМОНАЛЬНОГО ДИСБАЛАНСА ПРИ ЛЕЧЕНИИ СТАБИЛЬНОЙ СТЕНОКАРДИИ НАПРЯЖЕНИЯ10.25207:1608-6228-2018-25-3-51-55
- Plasma and cerebrospinal fluid beta-endorphin levels show a strong association in children with cerebral malaria
- Blood dopamine level enhanced by caffeine in men after treadmill runningPubmed: 31793465
- Blue light (λ= 453 nm) nitric oxide dependently induces β-endorphin production of human skin keratinocytes in-vitro and increases systemic β-endorphin levels in …Pubmed: 31553937
- Between pleasure and pain: a pilot study on the biological mechanisms associated with BDSM interactions in dominants and submissivesPubmed: 32044259
- Pain Sensitivity and Plasma Beta-Endorphin in Adolescent Non-Suicidal Self-InjuryPubmed: 32961416
- Serum β-endorphin levels are associated with addiction to suicidal behavior: a pilot studyPubmed: 32855024
- Efficacy of Acupuncture on Pain Mechanisms, Inflammatory Responses, and Wound Healing in the Acute Phase of Major Burns: An Experimental Study on Rats34309681
- Effects of transcutaneous electrical nerve stimulation applied at different frequencies during labor on hormone levels, labor pain perception, and anxiety: a randomized …