Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) Rattus norvegicus (Rat) Multiplex ELISA

TIG2; RARRES2; Tazarotene-Induced Gene 2; Retinoic Acid Receptor Responder 2,Tazarotene Induced; RAR-responsive protein TIG2

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMA945Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-91 87
EDTA plasma(n=5) 84-93 88
heparin plasma(n=5) 86-104 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-89% 99-105% 78-103% 92-104%
EDTA plasma(n=5) 96-103% 97-105% 79-90% 79-104%
heparin plasma(n=5) 80-88% 93-101% 86-97% 78-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CHEM) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

Giveaways

Citations

  • Serum chemerin and vaspin in non-alcoholic fatty liver diseasePubMed: 20095887
  • Chemerin, vaspin and insulin resistance in chronic hepatitis CWiley: source
  • Expression and regulation of chemerin during rat pregnancyScienceDirect: S0143400412000902
  • Chronic ethanol consumption increases the levels of chemerin in the serum and adipose tissue of humans and ratsNature: 201211
  • Ankilozan spondilitli hastalarda adipositokin düzeyleri ve insülin direnciRaeddergisi: Source
  • Association of chemerin with oxidative stress, inflammation and classical adipokines in non-diabetic obese patientsPubmed: 24702860
  • Strong correlations between circulating chemerin levels and lipoprotein subfractions in nondiabetic obese and nonobese subjectsPubmed: 24303851
  • Impact of OSA on Biological Markers in Morbid Obesity and Metabolic SyndromePubmed:24106991
  • Chemerin plays a protective role by regulating human umbilical vein endothelial cell-induced nitric oxide signaling in preeclampsiaPubmed:24840719
  • Relationship between plasma chemerin levels and disease severity in COPD patientsPubmed:24865134
  • Elevated serum chemerin in Chinese women with hyperandrogenic PCOSPubmed:24927079
  • Protective effect of liraglutide against ER stress in the liver of high-fat diet-induced insulin-resistant rats.Pubmed:25471281
  • Long-term Effect of Ileal Transposition on Adipokine Serum Level in Zucker (Orl)-Lepr fa Fatty RatsPubmed:25697126
  • Chemerin and calprotectin levels correlate with disease activity and inflammation markers in psoriasis vulgarisSciencedirect:S1027811714000470
  • Serum Chemerin Levels in relation to Osteoporosis and Bone Mineral Density: A Case-Control StudyPubMed: 26170530
  • Association of Serum Chemerin Levels with Acute Ischemic Stroke and Carotid Artery Atherosclerosis in a Chinese PopulationPubMed: 26471865
  • Protective effect of liraglutide against ER stress in the liver of high-fat diet-induced insulin-resistant ratsPubMed: 25471281
  • Effects of alpha-lipoic acid on chemerin secretion in 3T3-L1 and human adipocytesPubmed:26721419
  • Association of chemerin levels and bone mineral density in Chinese obese postmenopausalwomen.pubmed:27583869
  • Changes of Plasma FABP4, CRP, Leptin, and Chemerin Levels in relation to Different Dietary Patterns and Duodenal-Jejunal Omega Switch Surgery in Sprague …Pubmed:29849871
  • Chemerin is associated with diabetic retinopathy in type 2 diabetesPubmed:25848840
  • Expression of chemerin in the synovial fluid of patients with temporomandibular joint disordersPubmed:29331039
  • Epigenetic regulation of Amphiregulin and Epiregulin in colorectal cancerPubmed: 30252132
  • The decline of whole-body glucose metabolism in ovariectomized ratsPubmed: 30292771
  • Chemerin alleviates acute pancreatitis in the rat thorough modulation of NF-κB signalDoi: 10.1016/j.pan.2019.02.005
  • Protective effect of vitamin D supplementation in a rat modal of preeclampsia: a possible implication of chemerinPubmed: 30922121
  • Chemerin alleviates acute pancreatitis in the rat thorough modulation of NF-kB signalPubmed: 30833212
  • Association between High Levels of Circulating Chemerin and Colorectal Adenoma in MenPubmed: 31269491
  • Vitamin D Supplementation Reduces Serum Chemerin Level in Gestational Diabetes Mellitus Rat Model
  • Plasma levels of adiponectin and chemerin are associated with early stage of atherosclerosis in older adults with type 2 diabetes mellitus
  • The dietary inflammatory index is associated with anti-and pro-inflammatory adipokines in Brazilian schoolchildren33575861
  • Pro-and anti-inflammatory adipokines are associated with cardiometabolic risk markers in Brazilian schoolchildren33834274
  • Altered Serum Marker of Adipokines Profile in Breast Cancer Women
  • Association of High Serum Chemerin with Bone Mineral Density Loss and Osteoporotic Fracture in Elderly Chinese WomenPubmed:35140527

Recommend products