Multiplex Assay Kit for Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) Mus musculus (Mouse) Multiplex ELISA

C-Terminal Provasopressin; Vasopressin-Neurophysin 2-Copeptin

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMA365Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-104 101
EDTA plasma(n=5) 78-92 88
heparin plasma(n=5) 95-104 98
sodium citrate plasma(n=5) 90-104 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-96% 87-95% 92-104% 85-95%
EDTA plasma(n=5) 96-104% 98-105% 85-102% 95-103%
heparin plasma(n=5) 99-105% 98-105% 85-99% 80-94%
sodium citrate plasma(n=5) 78-98% 89-99% 93-101% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CPP) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Multiplex Assay Kit for Copeptin (CPP) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

Giveaways

Increment services

Citations

  • Copeptin: May it be a novel biomarker for insulin theraphy in diabetes? An animal study.Ejmanager: Source
  • Serum copeptin in children exposed to maltreatmentPubmed:27278269
  • Methods for Diagnosis and Treatment of Concussion or Brain Injury2016:0103140
  • Role of enteroendocrine L‐cells in arginine vasopressin‐mediated inhibition of colonic anion secretionPubmed:27037495
  • Can hypoxia enhance sexual arousal?-Molecular-biological analysis of the hypothalamus in male rats placed with oestrous female rats under hypoxic …files:ijcem0031358.pdf
  • Orthostatic Challenge Shifts the Hemostatic System of Patients Recovered from Stroke toward Hypercoagulability.pubmed:28223937
  • N-Terminal Prohormone of Brain Natriuretic Peptide but not C-Terminal Pre-Pro Vasopressin (Copeptin) Level is Associated with the Response to Antihypertensive …pubmed:29190613
  • Early Prediction of Preeclampsiajournals:297397
  • Evaluation of Urinary Aquaporin 2 and Plasma Copeptin as Biomarkers of Effectiveness of Desmopressin Acetate for the Treatment of Monosymptomatic Nocturnal Enuresis.pubmed:28457803
  • Experimental Heat Stress Nephropathy and Liver Injury are Improved by AllopurinolPubmed:29667911
  • Angiotensin AT Receptors Expressed in Vasopressin-Producing Cells of the Supraoptic Nucleus Contribute to the Osmotic Control of VasopressinPubmed:29364700
  • Rehydration with fructose worsens dehydration-induced renal damagePubmed:30005632
  • Copeptin level in the early prediction of cardiorenal syndrome in ratsPubmed:30112047
  • 和肽素水平对大鼠心肾综合征的早期预测价值filename:ZBLS201802013
  • Abstract P311: Static Urine Osmolality With Elevated First Trimester Urine Copeptin in Human Preeclampsia
  • Assessment of serum levels of copeptin and corticotropin-releasing factor in children with monosymptomatic and nonmonosymptomatic nocturnal enuresis
  • Cognitive performance is associated with cerebral oxygenation and peripheral oxygen saturation, but not plasma catecholamines, during graded normobaric hypoxia
  • Dialysate copeptin and peritoneal transport in incident peritoneal dialysis patientsPubmed: 31187425
  • The contribution of collecting duct NOS1 to the concentrating mechanisms in male and female micePubmed: 31241990
  • The increase of core temperature affected the progression of kidney injury by repeated heat stress exposurePubmed: 31390229
  • Deletion of the serine protease CAP2/Tmprss4 leads to dysregulated renal water handling upon dietary potassium depletionPubmed: 31863073
  • Copeptin is independently associated with vascular calcification in chronic kidney disease stage 5Pubmed: 32033584
  • Micro RNA 146a gene variant/TNF-α/IL-6/IL-1 β; A cross-link axis inbetween oxidative stress, endothelial dysfunction and neuro-inflammation in acute ischemic stroke …Pubmed: 31738890
  • Copeptin and Nesfatin-1 Are Interrelated Biomarkers with Roles in the Pathogenesis of Insulin Resistance in Chinese Children with ObesityPubmed: 33027789
  • Multimarker Approach to Identify Patients with Coronary Artery Disease at High Risk for Subsequent Cardiac Adverse Events: The Multi-Biomarker StudyPubmed: 32549327
  • Relation of Copeptin with Diabetic and Renal Function Markers Among Patients with Diabetes Mellitus Progressing Towards Diabetic NephropathyPubmed: 32505416
  • 重组人脑利钠肽治疗慢性肺心病急性加重期的临床效果及对5-HT 浓度的影响
  • Validity of different copeptin assays in the differential diagnosis of the polyuria-polydipsia syndrome33980941
  • Are the Circulating Levels of Copeptin and Fibronectin Dysregulated in Preeclamptic South African Black Women?
  • Copeptin levels are more elevated and associated with cardiovascular events in the unity of chronic ischemic heart and chronic kidney diseases
  • High serum copeptin may be a marker of an increased carotid intima-media thickness in asymptomatic patients with type 1 diabetes.
  • The Speed of Ingestion of a Sugary Beverage Has an Effect on the Acute Metabolic Response to Fructose
  • Dietary K+ acts as a genuine diureticPubmed:34984847
  • Spectrally multiplexed assay using gap enhanced nanoparticle for detection of a myocardial infarction biomarker panelPubmed:35190126
  • Arcuate NPY is involved in salt‐induced hypertension via modulation of paraventricular vasopressin and brain‐derived neurotrophic factorPubmed:35312067
  • Copeptin Concentrations in Plasma of Healthy Neonates in Relation to Water–Electrolyte Homeostasis in the Early Adaptation PeriodPubmed:35327814

Recommend products