Multiplex Assay Kit for Dihydrotestosterone (DHT) ,etc. by FLIA (Flow Luminescence Immunoassay) Pan-species (General) Multiplex ELISA

5α-DHT; 5α-Dihydrotestosterone; Androstanolone; Stanolone

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Dihydrotestosterone (DHT) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Dihydrotestosterone (DHT) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Dihydrotestosterone (DHT) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMA443Ge.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of Dihydrotestosterone (DHT) and the recovery rates were calculated by comparing the measured value to the expected amount of Dihydrotestosterone (DHT) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-101 98
EDTA plasma(n=5) 87-94 91
heparin plasma(n=5) 79-103 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Dihydrotestosterone (DHT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Dihydrotestosterone (DHT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Dihydrotestosterone (DHT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-96% 90-103% 97-105% 78-94%
EDTA plasma(n=5) 92-102% 95-105% 83-97% 93-105%
heparin plasma(n=5) 92-101% 86-103% 79-90% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:DHT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Dihydrotestosterone (DHT) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Dihydrotestosterone (DHT) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Dihydrotestosterone (DHT) and unlabeled Dihydrotestosterone (DHT) (Standards or samples) with the pre-coated antibody specific to Dihydrotestosterone (DHT). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Dihydrotestosterone (DHT) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Dihydrotestosterone (DHT) in the sample.

Giveaways

Increment services

Citations

  • Herbicide Metolachlor Causes Changes in Reproductive Endocrinology of Male Wistar RatsIsrn: 130846
  • Metabolic Changes and Hormonal Disturbances in Polycystic Ovarian Syndrome Rats and the Amelioration Effects of Metformin and/or Cinnamon ExtractionJofamericanscience: Source
  • Treatment of benign prostatic hyperplasia with Croton membranaceus in an experimental animal modelPubmed:25256687
  • Oral administration of low-dose bisphenol A promotes proliferation of ventral prostate and upregulates prostaglandin D2PubMed: 26088557
  • Testosterone Replacement Modulates Cardiac Metabolic Remodeling after Myocardial Infarction by Upregulating PPARαpubmed:27413362
  • Dihydrotestosterone Treatment Accelerates Autograft Reversal Sciatic Nerve Regeneration in RatsPubmed:29340845
  • Uterine progesterone signaling is a target for metformin therapy in polycystic ovary syndromePubmed: 29535146
  • Dihydrotestosterone synthesis in the sheep corpus luteum and its potential mechanism in luteal regressionPubmed: 30671954
  • Plant cell culture extract of Cirsium eriophorum with skin pore refiner activity by modulating sebum production and inflammatory responsePubmed: 32816329
  • Plasma Aromatase Activity Index, Gonadotropins and Estrone Are Associated with Frailty Syndrome in Post-Menopausal Women with Breast CancerPubmed:35323344
  • Syce1 and Syce3 regulate testosterone and dihydrotestosterone synthesis via steroidogenic pathways in mouse Sertoli and Leydig cellsPubmed:35697131

Recommend products