Multiplex Assay Kit for Fibrinogen Degradation Product (FDP) ,etc. by FLIA (Flow Luminescence Immunoassay)
FnDP; Fibrin Split Products; Fibrin Degradation Product
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 427.00 US$ 443.00 US$ 468.00 US$ 501.00 US$ 534.00 US$ 583.00 US$ 657.00 US$ 821.00
- Quantity
Overview
Properties
- Product No.LMA530Rb
- Organism SpeciesOryctolagus cuniculus (Rabbit) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryMetabolic pathwayHematologyCardiovascular biology
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Fibrinogen Degradation Product (FDP) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibrinogen Degradation Product (FDP) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 82-99 | 88 |
| EDTA plasma(n=5) | 97-105 | 101 |
| heparin plasma(n=5) | 85-99 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibrinogen Degradation Product (FDP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibrinogen Degradation Product (FDP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibrinogen Degradation Product (FDP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 80-98% | 92-101% | 78-104% | 84-98% |
| EDTA plasma(n=5) | 88-95% | 93-101% | 96-104% | 80-90% |
| heparin plasma(n=5) | 86-101% | 83-92% | 84-101% | 90-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:FDP) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Fibrinogen Degradation Product (FDP) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Fibrinogen Degradation Product (FDP) and unlabeled Fibrinogen Degradation Product (FDP) (Standards or samples) with the pre-coated antibody specific to Fibrinogen Degradation Product (FDP). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Fibrinogen Degradation Product (FDP) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Fibrinogen Degradation Product (FDP) in the sample.
Giveaways
Increment services
Citations
- The role of the E2F1 transcription factor in the innate immune response to systemic LPSPhysiology: Source
- Thrombomodulin alleviates murine GVHD in association with an increase in the proportion of regulatory T cells in the spleenPubmed:25243628
- The efficacy of recombinant human soluble thrombomodulin for the treatment of shiga toxin associated hemolytic uremic syndrome model micePubmed:25694534
- Inhibition of Plasmin Protects Against Colitis in Mice by Suppressing Matrix Metalloproteinase 9–Mediated Cytokine Release From Myeloid CellsSciencedirect:S0016508514014851
- Inhibition of Plasmin Protects Against Colitis in Mice byPubMed: 25490065
- Cytoprotective and pro-angiogenic functions of thrombomodulin are preserved in the C loop of the fifth epidermal growth factor-like domainPubmed:29903766
- Temporary inhibition of the plasminogen activator inhibits periosteal chondrogenesis and promotes periosteal osteogenesis during appendicular bone fracture …10.1016:j.bone.2018.04.016
- Nebulized anti-coagulants as a therapy for acute lung injury and acute respiratory distress syndromePubmed: 29202212
- Co-administration of iloprost and eptifibatide in septic shock (CO-ILEPSS)—a randomised, controlled, double-blind investigator-initiated trial investigating …Pubmed: 31488213
- Effects of nebulized antithrombin and heparin on inflammatory and coagulation alterations in an acute lung injury model in ratsPubmed: 31755229
