Multiplex Assay Kit for Filaggrin (FLG) ,etc. by FLIA (Flow Luminescence Immunoassay) Mus musculus (Mouse) Multiplex ELISA

Profilaggrin

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Filaggrin (FLG) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Filaggrin (FLG) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Filaggrin (FLG) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMJ103Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Filaggrin (FLG) and the recovery rates were calculated by comparing the measured value to the expected amount of Filaggrin (FLG) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-103 98
EDTA plasma(n=5) 95-105 101
heparin plasma(n=5) 84-103 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Filaggrin (FLG) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Filaggrin (FLG) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Filaggrin (FLG) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-105% 89-96% 78-101% 86-93%
EDTA plasma(n=5) 82-98% 90-99% 80-88% 93-105%
heparin plasma(n=5) 82-93% 89-101% 88-105% 85-92%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:FLG) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Filaggrin (FLG) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Filaggrin (FLG) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Filaggrin (FLG) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Filaggrin (FLG) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Filaggrin (FLG) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

Giveaways

Citations

  • Filaggrin R501x and 2282del4 gene mutations and its tissue levels in patients with chronic plaque psoriasisLWW: 01000
  • Neuromodulatory and Anti-Inflammatory Ingredient for Sensitive Skin: In Vitro Assessment Pubmed:24931812
  • Protective Effects of Triphala on Dermal Fibroblasts and Human KeratinocytesPubmed:26731545
  • In vitro anti-inflammatory and skin protective properties of extract comprising ceramides from de-oiled rice brandoi:10.1111
  • Imiquimod-induced psoriasis-like inflammation in differentiated Human keratinocytes: Its evaluation using curcumin.pubmed:28736282
  • A novel, topical, nonsteroidal, TRPV1 antagonist, PAC-14028 cream improves skin barrier function and exerts anti-inflammatory action through modulating epidermal …Pubmed:29752146
  • In vitro anti-inflammatory and skin protective properties of Virgin coconut oil10.1016:j.jtcme.2017.06.012
  • Markers of atopic dermatitis, allergic rhinitis and bronchial asthma in pediatric patients: correlation with filaggrin, eosinophil major basic protein and …
  • Filaggrin, major basic protein and leukotriene B4: Biomarkers for adult patients of bronchial asthma, atopic dermatitis and allergic rhinitisPubmed: 30560019
  • Epidermal and Dermal Hallmarks of Photoaging are Prevented by Treatment with Night Serum Containing Melatonin, Bakuchiol, and Ascorbyl …
  • 糖化に起因する表皮機能低下に対するワイルドタイムエキスの防御効果
  • Filaggrin‐gene mutation has minimal effect on the disease severity in the lesions of atopic dermatitis34322929