Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) Sus scrofa; Porcine (Pig) Multiplex ELISA

GSHPX3; GPx-P; GSHPx-P; GPXP; Plasma glutathione peroxidase; Extracellular glutathione peroxidase

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMC992Po.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-103 98
EDTA plasma(n=5) 90-104 96
heparin plasma(n=5) 92-99 96
sodium citrate plasma(n=5) 94-102 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 95-102% 89-96% 84-105%
EDTA plasma(n=5) 92-103% 83-97% 80-92% 89-98%
heparin plasma(n=5) 85-102% 80-96% 99-105% 90-102%
sodium citrate plasma(n=5) 80-92% 94-105% 85-99% 83-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GPX3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Multiplex Assay Kit for Glutathione Peroxidase 3, Plasma (GPX3) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

Giveaways

Citations

  • Alteration in the intrafollicular thiol–redox system in infertile women with endometriosisPubmed:25376627
  • Endothelial function impairment in STEMI patients with out-of-hospital cardiac arrest under therapeutic hypothermia treatment.pubmed:28087172
  • Comparison of Extracellular and Intracellular Blood Compartments Highlights Redox Alterations in Alzheimer's and Mild Cognitive Impairment Patients.pubmed:27748187
  • Burn Serum Increases Staphylococcus aureus Biofilm Formation via Oxidative Stress.pubmed:28702016
  • Hydrogen peroxide-induced mitophagy contributes to laryngeal cancer cells survival via the upregulation of FUNDC1Pubmed: 30284230
  • Kidney toxicity and response of selenium containing protein-glutathione peroxidase (Gpx3) to CdTe QDs on different levelsPubmed: 30535317
  • Human Plasma Protein (s) Based Conceptual Diagnostic Tool for Altitude-Acclimation Assessment
  • Dietary selenium deficiency or selenomethionine excess drastically alters organ selenium contents without altering the expression of most selenoproteins in mice
  • Molecular mechanisms of lead-induced changes of selenium status in mice livers through interacting with selenoprotein P
  • In vivo and in vitro studies on inactivation of selenium containing protein-glutathione peroxidase 3 in mice nephrocytes caused by leadPubmed: 32678766
  • Selenium–GPX4 axis protects follicular helper T cells from ferroptosis34413521
  • Experimental nephrotic syndrome in mice with an inducible deletion of podocin and the role of plasminogen in sodium retention

Recommend products