Multiplex Assay Kit for Indole 3 Acetic Acid (IAA) ,etc. by FLIA (Flow Luminescence Immunoassay)
IA-A; Indolylacetic Acid; Indoleacetic Acid; Heteroauxin
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 497.00 US$ 516.00 US$ 544.00 US$ 583.00 US$ 621.00 US$ 678.00 US$ 764.00 US$ 955.00
- Quantity
Overview
Properties
- Product No.LMA737Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategorySignal transductionHormone metabolism
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Indole 3 Acetic Acid (IAA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Indole 3 Acetic Acid (IAA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:IAA) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Indole 3 Acetic Acid (IAA) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Indole 3 Acetic Acid (IAA) and unlabeled Indole 3 Acetic Acid (IAA) (Standards or samples) with the pre-coated antibody specific to Indole 3 Acetic Acid (IAA). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Indole 3 Acetic Acid (IAA) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Indole 3 Acetic Acid (IAA) in the sample.
Giveaways
Increment services
Citations
- Assisted phytoremediation of mixed metal(loid)-polluted pyrite waste: effects of foliar and substrate IBA application on fodder radishPubMed: 21570105
- Contribution of indole-3-acetic acid in the plant growth promotion by the rhizospheric strain Bacillus amyloliquefaciens SQR9Springer:Source
- Structural and metabolic alterations in root systems under limited water conditions in forage grasses of Lolium-Festuca complex
- Indole-3-Acetic Acid Alleviates Nonalcoholic Fatty Liver Disease in Mice via Attenuation of Hepatic Lipogenesis, and Oxidative and Inflammatory StressPubmed: 31484323
