Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) Rattus norvegicus (Rat) Multiplex ELISA

OLR1; CLEC8A; SCARE1; Oxidized low-density lipoprotein receptor 1; C-type lectin domain family 8 member A; Lectin-like oxidized LDL receptor 1; Lectin-type oxidized LDL receptor 1

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMB859Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) and the recovery rates were calculated by comparing the measured value to the expected amount of Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 98
EDTA plasma(n=5) 89-98 93
heparin plasma(n=5) 96-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-99% 92-104% 80-94% 96-103%
EDTA plasma(n=5) 85-96% 95-104% 82-95% 94-102%
heparin plasma(n=5) 78-94% 95-102% 97-105% 85-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LOX1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Lectin Like Oxidized Low Density Lipoprotein Receptor 1 (LOX1) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

Giveaways

Citations

  • Circulating Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 Levels Are Associated With Angiographic Coronary Lesion Complexity in Patients With Coronary Artery DiseasPubMed: 21400544
  • Postprocedural serum sLOX-1 levels are associated with coronary in-stent restenosis in patients with stable coronary artery diseaseLWW: 06000
  • Soluble lectin-like oxidized low-density lipoprotein receptor-1 levels in synovial fluid are correlated with disease severity of knee osteoarthritisScienceDirect: S0009912011004905
  • Pregnancy Followed by Delivery May Affect Circulating Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 Levels in Women of Reproductive AgePubMed: 22619487
  • Lectin-like oxidized low density lipoprotein receptor 1(LOX-1) levels and endothelial dysfunction in patients with primary essential hyperhidrosis/Primer esansiyel hiperhidroz hastalarinda lektin benzeri okside düsük dansiteli lipoprotein reseptor 1(LOX-1) düzeyleri ve endotel disfonksiyonuReadperiodicals: Source
  • Soluble Lectin-Like Oxidized LDL Receptor 1 as a Possible Mediator of Endothelial Dysfunction in Patients With Metabolic SyndromePubmed:24798146
  • Endothelial damage in white coat hypertension: role of lectin-like oxidized low-density lipoprotein-1Pubmed:25007999
  • Inhibition of Lectin-Like Oxidized Low-Density Lipoprotein Receptor 1 Protects against Plasma/Hypoxia-Mediated Trophoblast Dysfunction Associated with PreeclampsiaPubmed:25633310
  • Increased serum soluble lectin-like oxidized low-density lipoprotein receptor-1 levels in patients with biopsy-proven nonalcoholic fatty liver diseasePubMed: 26185381
  • Serum sLOX-1 Levels Are Correlated with the Presence and Severity of Obstructive Sleep ApneaPubMed: 25825846
  • 27-Hydroxycholesterol regulates cholesterol synthesis and transport in C6 glioma cells.pubmed:28167099
  • Increased Levels of Lectin‐Like Oxidized Low‐Density Lipoprotein Receptor‐1 in Ischemic Stroke and Transient Ischemic AttackPubmed:29330254
  • Higher serum lectin-like oxidized low-density lipoprotein receptor-1 in patients with stable coronary artery disease is associated with major adverse …
  • Baseline Serum sLOX-1 Concentrations Are Associated with 2-Year Major Adverse Cardiovascular and Cerebrovascular Events in Patients after Percutaneous …Pubmed: 31772687
  • Polycystic ovary syndrome and endothelial dysfunction: A potential role for soluble lectin-like oxidized low density lipoprotein receptor-1Pubmed: 32409108
  • The oxidized‐LDL/LOX‐1 axis in tumor endothelial cells enhances metastasis by recruiting neutrophils and cancer cellsPubmed:35608341

Recommend products