Multiplex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) Rattus norvegicus (Rat) Multiplex ELISA

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMB934Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) and the recovery rates were calculated by comparing the measured value to the expected amount of Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-101 97
EDTA plasma(n=5) 89-96 93
heparin plasma(n=5) 96-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 97-104% 83-93% 80-89%
EDTA plasma(n=5) 79-93% 94-102% 88-96% 82-97%
heparin plasma(n=5) 79-91% 87-101% 88-103% 91-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LRG1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

Giveaways

Citations

  • Differentially expressed urinary biomarkers in children with idiopathic nephrotic syndromePubMed: 26351173
  • Targeted proteomics predict a sustained complete-response after transarterial chemoembolization and clinical outcomes in patients with hepatocellular carcinoma: a prospective cohort studypubmed:28112944
  • leucine-rich alpha-2-glycoprotein-1 is up-regulated in colorectal cancer and is a tumor promoterPubmed:29785123
  • Screening and Identification of Pregnancy Zone Protein (PZP) and Leucine‐Rich Alpha‐2‐Glycoprotein (LRG) as Potential Serum Biomarkers for Early‐onset …Pubmed: 30411527
  • iTRAQ-based quantitative protein expression profiling of biomarkers in childhood B-cell and T-cell acute lymphoblastic leukemiaPubmed: 31440093
  • A Three-Protein Panel to Support the Diagnosis of Sepsis in ChildrenPubmed:35329889

Recommend products