Multiplex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. by FLIA (Flow Luminescence Immunoassay) Mus musculus (Mouse) Multiplex ELISA

POU5F1; OCT3; OTF3; OTF4; Octamer-4; POU Domain Class 5 Transcription Factor 1; POU Class 5 Homoeobox 1; Octamer-binding protein 3

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMA424Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Octamer Binding Transcription Factor 4 (OCT4) and the recovery rates were calculated by comparing the measured value to the expected amount of Octamer Binding Transcription Factor 4 (OCT4) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 97
EDTA plasma(n=5) 81-90 85
heparin plasma(n=5) 89-97 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Octamer Binding Transcription Factor 4 (OCT4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Octamer Binding Transcription Factor 4 (OCT4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-102% 89-103% 87-95% 80-91%
EDTA plasma(n=5) 96-104% 96-105% 96-105% 98-105%
heparin plasma(n=5) 87-97% 88-97% 83-98% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:OCT4) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Octamer Binding Transcription Factor 4 (OCT4) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Octamer Binding Transcription Factor 4 (OCT4) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Octamer Binding Transcription Factor 4 (OCT4) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Octamer Binding Transcription Factor 4 (OCT4) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Octamer Binding Transcription Factor 4 (OCT4) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

Giveaways

Citations

  • A universal glucometer-based biosensor for portable and quantitative detection of transcription factorsRsc: Source
  • Upregulation of stem cell markers ALDH1A1 and OCT4 as potential biomarkers for the early detection of cervical carcinomaDoi: 10.3892/ol.2018.9381
  • Generation of two induced pluripotent stem cell lines NCCSi005A and NCCSi006A from CD4+ T cells of healthy individuals of Indian origin
  • Experimental and Modeling Framework for the Production of Cell and Protein-Based Biopharmaceutical Products
  • Generation and characterization of three clones (NCCSi007A, NCCSi007B and NCCSi007C) of an integration free induced Pluripotent Stem Cell line from a …Pubmed: 31862609
  • Studies on male gonadal toxicity of bisphenol A in diabetic rats: An example of exacerbation effectPubmed:35187753

Recommend products