Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) Homo sapiens (Human) Multiplex ELISA

UII; U-II; UCN2; PRO1068; Urotensin-II

(Note: Up to 8-plex in one testing reaction)

Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay) Results demonstration
  • LMA362Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Urotensin 2 (UST2) and the recovery rates were calculated by comparing the measured value to the expected amount of Urotensin 2 (UST2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 98
EDTA plasma(n=5) 83-95 89
heparin plasma(n=5) 92-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urotensin 2 (UST2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urotensin 2 (UST2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Urotensin 2 (UST2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-96% 78-97% 80-95% 98-105%
EDTA plasma(n=5) 83-97% 84-98% 95-103% 89-103%
heparin plasma(n=5) 85-97% 83-97% 78-91% 87-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:UST2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Urotensin 2 (UST2) ,etc. by FLIA (Flow Luminescence Immunoassay)

Test principle

Anti-Urotensin 2 (UST2) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Urotensin 2 (UST2) and unlabeled Urotensin 2 (UST2) (Standards or samples) with the pre-coated antibody specific to Urotensin 2 (UST2). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Urotensin 2 (UST2) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Urotensin 2 (UST2) in the sample.

Giveaways

Citations

  • Serum Urotensin II Levels in Patients with Non-Dipper HypertensionPubmed: 23301552
  • Urotensin II (U-II), a novel cyclic peptide, possibly associated with the pathophysiology of osteoarthritisPubmed: 24468547
  • Urotensin-II level and its association with oxidative stress in early diabetic nephropathy.pubmed:25179234
  • Acute Biochemical, Cardiovascular, and Autonomic Response to Hyperbaric (4 atm) Exposure in Healthy SubjectsPubmed:29977313
  • The Relationship of the Urotensin-2 Level in the Aqueous Humor with Systemic Diseases and Pupil Size: Comparative StudyPubmed: 33147089
  • Boy kısalığı olan çocukların serum ürotensin 2 düzeylerinin igf-1 ile ilişkisi.

Recommend products