Multiplex Assay Kit for 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) Homo sapiens (Human) Protein, Antibody, Assaykit, Service

11DH; 11-beta-HSD1; HDL; HSD11; HSD11B; HSD11L; SDR26C1; Corticosteroid 11-beta-dehydrogenase isozyme 1; Short Chain Dehydrogenase/Reductase Family 26C,Member 1

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 588.00 US$ 840.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-94 87
EDTA plasma(n=5) 87-95 91
heparin plasma(n=5) 93-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-101% 96-104% 78-99% 78-101%
EDTA plasma(n=5) 78-95% 79-95% 83-91% 87-103%
heparin plasma(n=5) 79-97% 97-104% 95-104% 96-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • Uninephrectomy reduces 11β-hydroxysteroid dehydrogenase type 1 and type 2 concomitantly with an increase in blood pressure in rats PubMed: 22739210
  • Anti-Inflammatory Property ofPubMed: 26300946
  • Piper sarmentosum Effects on 11β-Hydroxysteroid Dehydrogenase Type 1 Enzyme in Serumand Bone in Rat Model of Glucocorticoid-Induced Osteoporosis.pubmed:27854305
  • A novel derivatives of thiazol-4 (5H)-one and their activity in the inhibition of 11β-hydroxysteroid dehydrogenase type 1Pubmed:29738970
  • An Evidence-Based Review: The Effects of Malaysian Traditional Herbs on Osteoporotic Rat Models
  • Application of ELISA Technique and Human Microsomes in the Search for 11β-Hydroxysteroid Dehydrogenase InhibitorsDoi: BioMed Research International
  • Synthesis of the N‐methyl derivatives of 2‐aminothiazol‐4 (5H)‐one and their interactions with 11βHSD1‐molecular modeling and in vitro studiesPubmed: 31012543
  • Hepatoprotective Effects of Morinda citrifolia Leaf Extract on Ovariectomized Rats Fed with Thermoxidized Palm Oil Diet: Evidence at Histological and Ultrastructural …Pubmed: 31827717

Recommend products