Multiplex Assay Kit for Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array)
ANHU; SERPINA8; Angiotensin; Renin Substrate; Serpin Peptidase Inhibitor,Clade A,Member 8(Alpha-1 Antiproteinase,Antitrypsin)
Overview
Properties
- Product No.CMA797Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryCardiovascular biology
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 81-91 | 86 |
| EDTA plasma(n=5) | 97-105 | 101 |
| heparin plasma(n=5) | 84-91 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 90-105% | 79-101% | 93-102% | 85-102% |
| EDTA plasma(n=5) | 80-97% | 83-91% | 92-102% | 94-101% |
| heparin plasma(n=5) | 94-105% | 96-105% | 97-104% | 91-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Angiotensinogen (AGT) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.
Giveaways
Increment services
Citations
- Elevated urinary angiotensinogen a marker of intrarenal renin angiotensin system in hypertensive renal transplant recipients: does it play a role in development of proteinuria in hypertensive renal transplant patients?Wiley: source
- The relation between urinary angiotensinogen and proteinuria in renal AA amyloidosis patientsPubMed: 22320202
- Urinary angiotensinogen as a marker of intrarenal angiotensin II activity in adolescents with primary hypertensionPubMed: PMC3661928
- Urinary angiotensinogen as a novel marker of obstructive nephropathy in childrenPubmed: 23772991
- Association between urinary angiotensinogen, hypertension and proteinuria in pregnant women with preeclampsiaSagepub: Source
- MP707 CHARACTERISTICS AND OUTCOMES OF CHILDREN WITH AUTOSOMAL RECESSIVE POLYCYSTIC KIDNEY DISEASE COHORT FROM THE ESPN/ERA-EDTA REGISTRYOxfordjournals:Source
- Relationship between blood pressure varPubMed: 26223347
- Higher Serum Angiotensinogen Is an Indicator of IgA Vasculitis with Nephritis Revealed by Comparative Proteomes AnalysisPubMed: 26098644
- Korelasi pengukuran antropometri dengan tekanan darah dan angiotensinogen plasma pada dewasaIndex.Php: Art
- Relationship between blood pressure variability and renal activity of the renin-angiotensin system.pubmed:26223347
- Pharmacological evidence: a new therapeutic approach to the treatment of chronic heart failure through SUR2B/Kir6.1 channel in endothelial cells.pubmed:27890915
- Application of a new procedure for liquid chromatography/mass spectrometry profiling of plasma amino acid-related metabolites and untargeted shotgun proteomics to identify mechanisms and biomarkers of calcific aortic stenosisS0021967317311858
- Pyrrolidine dithiocarbamate inhibits mouse acute kidney injury induced by diclofenac by targeting oxidative damage, cytokines and NF-κB activityPubmed:30036488
- Role of (Pro) Renin Receptor in Albumin Overload-Induced Nephropathy in RatsPubmed:29846109
- Quantitation of Total and Free Thiol Angiotensinogen as a Prognostic Marker for PreeclampsiaPubmed: 31069778
- Multi-omic signatures of atherogenic dyslipidaemia: pre-clinical target identification and validation in humans33407555
- Association of Ang-(1¨C7) and des-Arg 9 BK as new biomarkers of obesity and cardiometabolic risk factors in adolescents33568792
- (Pro) renin receptor antagonist PRO20 attenuates nephrectomy©\induced nephropathy in rats via inhibition of intrarenal RAS and Wnt/¦Â©\catenin signaling34057312
- A novel strategy to identify candidate diagnostic and prognostic biomarkers for gastric cancer34215253