Multiplex Assay Kit for Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) Rattus norvegicus (Rat) Protein, Antibody, Assaykit, Service

ATG6; VPS30; Coiled-Coil,Myosin-Like BCL2 Interacting Protein; ATG6 Autophagy Related 6 Homolog

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 638.00 US$ 912.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-105 99
EDTA plasma(n=5) 92-101 96
heparin plasma(n=5) 91-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-104% 82-97% 92-99% 88-102%
EDTA plasma(n=5) 92-99% 88-103% 90-98% 83-90%
heparin plasma(n=5) 95-102% 81-101% 84-99% 78-90%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Beclin 1 (BECN1) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • Can Enhanced Autophagy be Associated with Human Longevity? Serum Levels of the Autophagy Biomarker Beclin-1 are Increased in Healthy CentenariansPubmed:25307612
  • A peel-off facial mask comprising myoinositol and trehalose-loaded liposomes improves adult female acne by reducing local hyperandrogenism and activating autophagypubmed:28342238
  • The novel CXCR4 antagonist, PRX177561, reduces tumor cell proliferation and accelerates cancer stem cell differentiation in glioblastoma preclinical modelspubmed:28639900
  • Beclin1 circulating levels and accelerated ageing markers in COPD DOI: 10.1183/1393003.congress-2017.PA1018
  • Beclin1 circulating levels and accelerated aging markers in COPDPubmed:29402890
  • A novel combined score of biomarkers in sputum may be an indicator for lung cancer: A pilot studyDoi: 10.1016/j.cca.2018.09.027
  • Serum concentration of autophagy-related protein 7 is correlated with non-alcoholic fatty liver disease in Chinese adults
  • Crosstalk between vitamin D axis, inflammation and host immunity mechanisms: A prospective study33936265
  • Inhibition of HepG-2 Cells (Liver Cancer Cell Line) Viability by 3-Hydroxypyridine-2-Carboxaldehyde N (4)-Methylthiosemicarbazone
  • BIOMARKERS OF AUTOPHAGY AND ANTIVIRAL ROLE OF PLACENTA FOR PREDICTING PRETERM DELIVERY IN PATIENTS WITH PRETERM DELIVERY?¡­
  • IDENTIFICATION OF FACTORS CONNECTED WITH AUTOPHAGY ACTIVITY UNDER CONDITIONS OF PARTIAL NUTRITIONAL DEPRIVATION IN MEN

Recommend products