Multiplex Assay Kit for Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) Rattus norvegicus (Rat) Protein, Antibody, Assaykit, Service

CTNNb1; bCat; b-Cat; CTNN-B1; Catenin Beta 1; Cadherin-Associated Protein

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 606.00 US$ 866.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-95 92
EDTA plasma(n=5) 83-97 94
heparin plasma(n=5) 86-94 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-104% 87-96% 97-104% 80-101%
EDTA plasma(n=5) 81-91% 89-103% 90-98% 94-105%
heparin plasma(n=5) 88-101% 80-98% 80-101% 80-89%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Beta Catenin (β-catenin) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • Versican and its associated molecules: Potential diagnostic markers for multiple myelomaPubmed:25623955
  • Adverse effects of osteocytic constitutive activation of ?-catenin on bone strength and bone growthPubmed:25639729
  • Role of SDF-1 and Wnt signaling pathway in the myocardial fibrosis of hypertensive ratsPubMed: 26396666
  • Is there an association between enhanced choline and β-catenin pathway in breast cancer? A pilot study by MR Spectroscopy and ELISA.pubmed:28533512
  • Hepatoprotective effect of hesperidin in hepatocellular carcinoma: Involvement of Wnt signaling pathways.pubmed:28754618
  • Is there an association between enhanced choline and β-catenin pathway in breast cancer? A pilot study by MR Spectroscopy and ELISAPubmed: 28533512
  • Eribulin Treatment Induces High Expression of miR-195 and Inactivates the Wnt/β-catenin Signaling Pathway in Triple-negative Breast CancerDoi: 10.15369/sujms.30.359
  • Urinary procollagen III aminoterminal propeptide and β-catenin–New diagnostic biomarkers in solitary functioning kidney?Pubmed: 30738287
  • Silence of FAM83H-AS1 promotes chemosensitivity of gastric cancer through Wnt/β-catenin signaling pathwayPubmed: 32028241
  • Novel complex of cosmetic ingredients with promising action in preventing hair loss and follicular aging through mechanism involving enrichment of WNT/signaling …Pubmed: 33179848
  • Hydroxytyrosol as a Promising Ally in the Treatment of FibromyalgiaPubmed: 32784915
  • Amalgamation of PI3K and EZH2 blockade synergistically regulates invasion and angiogenesis: combination therapy for glioblastoma multiforme33473259
  • QNZ alleviated hepatocellular carcinoma by targeting inflammatory pathways in a rat model34564023

Recommend products