Multiplex Assay Kit for Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array)
C7orf1; CPE-R2; CPETR2; HRVP1; RVP1; Clostridium Perfringens Enterotoxin Receptor 2; Ventral Prostate.1-Like Protein; CPE-Receptor 2
Overview
Properties
- Product No.CMF293Ca
- Organism SpeciesCanis familiaris; Canine (Dog) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategorySignal transduction
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 79-104 | 95 |
| EDTA plasma(n=5) | 99-105 | 102 |
| heparin plasma(n=5) | 92-99 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 80-103% | 98-105% | 87-101% | 86-94% |
| EDTA plasma(n=5) | 99-105% | 81-98% | 96-103% | 88-96% |
| heparin plasma(n=5) | 92-103% | 92-99% | 82-94% | 89-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:CLDN3) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) and unlabeled Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Claudin 3 (CLDN3) ,etc. by CBA (Cytometric Bead Array) in the sample.
Giveaways
Increment services
Citations
- Gastrointestinal response and endotoxemia during intense exercise in hot and cool environmentsPubmed: 23314685
- Effects of probiotics supplementation on gastrointestinal permeability, inflammation and exercise performance in the heatSpringer: Source
- Clinical Characteristics Associated With Postoperative Intestinal Epithelial Barrier Dysfunction in Children With Congenital Heart Disease*PubMed: 25162512
- Reinforcement of intestinal epithelial barrier by arabinoxylans in overweight and obese subjects: A randomized controlled trial: Arabinoxylans in gut barrier.pubmed:28214040
- Plasma claudin-3 is associated with tumor necrosis factor-alpha-induced intestinal endotoxemia in liver diseasePubmed: 31053499
- Intestinal Permeability in Children with Celiac Disease after the Administration of Oligofructose-Enriched Inulin into a Gluten-Free Diet—Results of a Randomized …Pubmed: 32531982
- Markers of Intestinal Damage in Individuals with and without Obesity during a 12-Week Exercise Period.
- Dysbiosis and Intestinal Barrier Dysfunction in Pediatric Congenital Heart Disease is Exacerbated Following Cardiopulmonary Bypass
- Short-Term Very High Carbohydrate Diet and Gut-Training Have Minor Effects on Gastrointestinal Status and Performance in Highly Trained Endurance AthletesPubmed:35565896