Multiplex Assay Kit for Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) Mus musculus (Mouse) Protein, Antibody, Assaykit, Service

C1-q; Autoantigen Clq

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 545.00 US$ 778.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-90 85
EDTA plasma(n=5) 86-103 93
heparin plasma(n=5) 80-105 80

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-103% 81-91% 78-93% 79-103%
EDTA plasma(n=5) 96-105% 90-101% 84-101% 80-97%
heparin plasma(n=5) 92-105% 80-95% 80-96% 87-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Increment services

Citations

  • Complement activation contributes to the injury and outcome of kidney in human anti-glomerular basement membrane disease.PubMed: 22941511
  • Characterization of complement 1q binding protein of tiger shrimp, Penaeus monodon, and its C1q binding activityPubmed: 23085472
  • Acute and prolonged complement activation in the central nervous system during herpes simplex encephalitisPubmed:27235358
  • The role of complement components C1q, MBL and C1 inhibitor in pathogenesis of endometriosisPubmed:29572748
  • Intrathecal complement activation by the classical pathway in tick-borne encephalitisPubmed: 30850976
  • Complement activation profile of patients with primary focal segmental glomerulosclerosisPubmed: 32569286
  • Liver Immune Profiling Reveals Pathogenesis and Therapeutics for Biliary Atresia33248023
  • Plasma and urine complement activation products in light chain and heavy chain deposition disease
  • Matrine treatment induced an A2 astrocyte phenotype and protected the blood-brain barrier in CNS autoimmunity34280490
  • Elevated Serum Complement C1q Levels After Traumatic Brain Injury and Its Association with Poor PrognosisPubmed:35035218

Recommend products