Multiplex Assay Kit for Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) Oryctolagus cuniculus (Rabbit) Protein, Antibody, Assaykit, Service

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 575.00 US$ 821.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-105 102
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 79-104 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-91% 96-105% 85-104% 95-105%
EDTA plasma(n=5) 82-99% 85-104% 86-101% 92-101%
heparin plasma(n=5) 86-104% 81-96% 98-105% 96-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Complement Component 3a (C3a) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Increment services

Citations

  • Immobilization of soluble complement receptor 1 on islets.ScienceDirect: S0142961211002596
  • Elevated complement factor C5a in maternal and umbilical cord plasma in preeclampsiaPubMed: 23415845
  • Efficacy of a synthetic antimicrobial peptidomimetic versus vancomycin in a Staphylococcus epidermidis device-related murine peritonitis modelPubmed: 23645587
  • Therapeutic effects of sesame oil on monosodium urate crystal-induced acute inflammatory response in ratsPubmed: 24353977
  • Complement Split Products C3a/C5a and Receptors: Are They Regulated by Circulating Angiotensin II Type 1 Receptor Autoantibody in Severe Preeclampsia?PubMed: 26485247
  • Human IgG Antinuclear Antibodies Induce Pregnancy Loss in Mice by Increasing Immune Complex Deposition in Placental Tissue: In Vivo StudyPubMed: 26388133
  • Acute and prolonged complement activation in the central nervous system during herpes simplex encephalitisPubmed:27235358
  • Alternative Pathway Inhibition by Exogenous Factor H Fails to Attenuate Inflammation and Vascular Leakage in Experimental Pneumococcal Sepsis in MicePubmed:26872035
  • Dosagem de frações ativadas do sistema complemento em empiema induzido em ratos10183
  • Interaction of gold and silver nanoparticles with human plasma: Analysis of protein corona reveals specific binding patterns.pubmed:28131092
  • Accuracy of complement activation product levels to detect infected pleural effusion in ratspubmed:28474458
  • The Complement C3a–C3aR Axis Promotes Development of Thoracic Aortic Dissection via Regulation of MMP2 ExpressionPubmed:29367209
  • Long term safety and immunological effects of a nanobiotherapeutic, bovine poly-[hemoglobin-catalase-superoxide dismutase-carbonic anhydrase], after four weekly …Pubmed:29873524
  • Mesenchymal stromal cell secretory factors induce sustained improvements in islet function pre-and post-transplantationDoi: 10.1016/j.jcyt.2018.07.007
  • Intrathecal complement activation by the classical pathway in tick-borne encephalitisPubmed: 30850976
  • Pathogenic roles of anti-C1q antibodies in recurrent pregnancy loss
  • Hemocompatibility of biodegradable Zn-0.8 wt%(Cu, Mn, Li) alloys
  • Complement-mediated hypersensitivity reactions to an amphotericin B-containing lipid complex (Abelcet) in pediatric patients and anesthetized rats: Benefits of slow infusion33549818
  • Increased ratios of complement factors C3a to C3 in aqueous humor and serum mark glaucoma progression33493474
  • C‐reactive protein inhibits C3a/C3aR‐dependent podocyte autophagy in favor of diabetic kidney diseasePubmed:35503088

Recommend products