Multiplex Assay Kit for Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) Rattus norvegicus (Rat) Protein, Antibody, Assaykit, Service

CF-B; BF; BFD; CFAB; GBG; H2-Bf; PBF2; B-Factor; Properdin; Properdin factor B; C3/C5 convertase; Glycine-rich beta glycoprotein

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 638.00 US$ 912.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-99 95
EDTA plasma(n=5) 84-93 87
heparin plasma(n=5) 90-104 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-94% 80-91% 92-105% 82-90%
EDTA plasma(n=5) 80-102% 85-93% 83-91% 98-105%
heparin plasma(n=5) 88-97% 84-101% 78-97% 95-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Complement Factor B (CFB) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • Complement in patients receiving maintenance hemodialysis: functional screening and quantitative analysisBioMed: 14712369
  • Identification and Confirmation of Differentially Expressed Fucosylated Glycoproteins in the Serum of Ovarian Cancer Patients Using a Lectin Array and LC–MS/MSACS: pr300330z
  • Atypical hemolytic uremic syndrome: Korean pediatric seriesPubMed: 25443527
  • Acute and prolonged complement activation in the central nervous system during herpes simplex encephalitisPubmed:27235358
  • Adipose tissue complement factor B promotes adipocyte maturation.pubmed:29137982
  • Serum exosomes from newborn piglets restrict porcine epidemic diarrhea virus infection
  • Identification of susceptibility locus shared by IgA nephropathy and inflammatory bowel disease in a Chinese Han populationPubmed: 31857673
  • Association between thrombotic microangiopathy and activated alternative complement pathway in malignant nephrosclerosis33367879
  • Changes in complement alternative pathway components, factor B and factor H during dengue virus infection in the AG129 mouse33410734
  • Early Diagnostic Ability of Human Complement Factor B in Pancreatic Cancer Is Partly Linked to Its Potential Tumor-Promoting Role34766501
  • A Three-Protein Panel to Support the Diagnosis of Sepsis in ChildrenPubmed:35329889

Recommend products