Multiplex Assay Kit for Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array)
GOLM1; GP73; C9orf155; Golgi Membrane Protein 1; Golgi Protein 73
Overview
Properties
- Product No.CMB668Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryTumor immunityInfection immunityReproductive scienceHepatology
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 92-102 | 96 |
| EDTA plasma(n=5) | 83-103 | 90 |
| heparin plasma(n=5) | 81-99 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 80-101% | 78-90% | 92-99% | 79-90% |
| EDTA plasma(n=5) | 98-105% | 95-105% | 85-94% | 83-94% |
| heparin plasma(n=5) | 88-103% | 96-105% | 79-103% | 93-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Golgi Phosphoprotein 2 (GOLPH2) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.
Giveaways
Increment services
Citations
- LAMC2: A promising new pancreatic cancer biomarker identified by proteomic analysis of pancreatic adenocarcinoma tissuesMcponline: 023507
- Diagnostic and Prognostic Validity of Serum Golgi Protein 73 in Egyptian Patients with Hepatocelluar CarcinomaAjied: Ajied_System_Files
- Diagnostic role of Golgi protein 73 and IL-17 in Egyptian cirrhotic rather than hepatocellular carcinoma patients.handle:123456789
- Serum Golgi protein 73 is a prognostic rather than diagnostic marker in hepatocellular carcinomapubmed:29113278
- The possible role of Dickkopf-1, Golgi protein-73 and Midkine as predictors of hepatocarcinogenesis: a review and an Egyptian studyPubmed: 32198440
- Dynamic expression of hepatic GP73 mRNA and protein and circulating GP73 during hepatocytes malignant transformationPubmed: 32171652
- Deoxycholic Acid Upregulates Serum Golgi Protein 73 through Activating NF-¦ÊB Pathway and Destroying Golgi Structure in Liver Disease. Biomolecules 2021, 11?¡33540642
- Search for Effective Serum Tumor Markers for Early Diagnosis of Hepatocellular Carcinoma Associated with Hepatitis C