Multiplex Assay Kit for Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) Rattus norvegicus (Rat) Protein, Antibody, Assaykit, Service

CD121a; CD121-A; IL1-R1; IL1R; IL1RA; P80; CD121 Antigen-Like Family Member A; Interleukin-1 Receptor Alpha

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 669.00 US$ 955.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-97 91
EDTA plasma(n=5) 90-102 95
heparin plasma(n=5) 87-101 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 95-105% 84-92% 89-103%
EDTA plasma(n=5) 97-104% 80-96% 99-105% 78-96%
heparin plasma(n=5) 90-99% 90-104% 80-97% 79-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Interleukin 1 Receptor Type I (IL1R1) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • In vivo extravasation induces expression of IL-1R1 in human neutrophilsWiley: source
  • The Gene Expression Analysis of Blood Reveals S100A11 and AQP9 as Potential Biomarkers of Infective EndocarditisPlosone: 0031490
  • Kinetics of the soluble IL-1 receptor type I during treatment with an LCAP filter in patients with inflammatory bowel diseasePubMed: 22267087
  • A Combinatorial Relative Mass Value Evaluation of Endogenous Bioactive Proteins in Three-Dimensional Cultured Nucleus Pulposus Cells of Herniated Intervertebral Discs: Identification of Potential Target Proteins for Gene Therapeutic ApproachesPlosone: Source
  • IL1R1 基因多态性与儿童哮喘的相关性article:13877
  • IL-1α regulates osteogenesis and osteoclastic activity of dental follicle cells via JNK and p38 MAPK pathwaysPubmed: 33107399
  • Salvadora persica extract attenuates cyclophosphamide-induced hepatorenal damage by modulating oxidative stress, inflammation and apoptosis in ratsPubmed:35643766

Recommend products