Multiplex Assay Kit for Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) Pan-species (General) Protein, Antibody, Assaykit, Service

LX-A4

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 679.00 US$ 970.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 97
EDTA plasma(n=5) 92-101 97
heparin plasma(n=5) 78-96 89

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 88-96% 86-101% 83-101%
EDTA plasma(n=5) 88-102% 82-90% 78-89% 96-105%
heparin plasma(n=5) 91-98% 85-92% 86-104% 86-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LXA4) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) and unlabeled Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Lipoxin A4 (LXA4) ,etc. by CBA (Cytometric Bead Array) in the sample.

Giveaways

Increment services

Citations

  • Redox modulation of cellular stress response and lipoxin A4 expression by Coriolus versicolor in rat brain: Relevance to Alzheimer&#039;s disease pathogenesisPubMed: 26433056
  • Redox modulation of cellular stress response and lipoxin A4 expression by Hericium Erinaceus in rat brain: relevance to Alzheimer's disease pathogenesis.pubmed:27398086
  • Acute coronary syndrome and acute kidney injury: role of inflammation in worsening renal functionpubmed:28747177
  • CDP‐choline protects liver from ischemia/reperfusion injury preserving mitochondrial function and reducing oxidative stressPubmed:29679463
  • Leukocyte CD300a Contributes to the Resolution of Murine Allergic InflammationPubmed: 30315138
  • Dynamic changes and clinical significance of LXA4 in the perioperative period of cardiopulmonary bypass
  • Lipoxin A4-Mediated p38 MAPK Signaling Pathway Protects Mice Against Collagen-Induced Arthritis33221976
  • The mimetic peptide Ac2-26 of annexin A1 attenuates inflammation and apoptosis in sepsis-induced acute kidney injury

Recommend products