Multiplex Assay Kit for Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array)
Protein-Lysine 6-Oxidase
Overview
Properties
- Product No.CMC580Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryEnzyme & Kinase
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 82-95 | 87 |
| EDTA plasma(n=5) | 96-103 | 99 |
| heparin plasma(n=5) | 91-101 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 82-94% | 84-92% | 96-103% | 90-101% |
| EDTA plasma(n=5) | 97-105% | 80-101% | 96-103% | 95-103% |
| heparin plasma(n=5) | 80-94% | 83-94% | 88-104% | 78-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Lysyl Oxidase (LOX) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.
Giveaways
Increment services
Citations
- The expression of lysyl-oxidase gene family members in myeloproliferative neoplasms.PubMed: 23494965
- High Glucose Induced Differential Expression of Lysyl Oxidase and Its Isoform in ARPE-19 CellsPubmed: 22966818
- Evaluation of serum lysyl oxidase as a blood test for colorectal cancer Pubmed: 24246612
- Copia autorizada por CDRIngentaconnect: Source
- Lysyl oxidase is a potential biomarker of fibrosis in systemic sclerosisPubmed: 24574233
- Evaluation of serum lysyl oxidase as a blood test for colorectal cancerPubmed:Pmc4237001
- Ionizing radiation induces tumor cell lysyl oxidase secretionPubmed:Pmc4223762
- Lysyl Oxidase Genetic Variants Affect Gene Expression in Cervical CancerPubmed:24945327
- Increased Serum Levels of the IL-33 Neutralizing sST2 in Limited Cutaneous Systemic SclerosisPubMed: 26095613
- Correlation of Aqueous Humor Lysyl Oxidase Activity with TGF-ß Levels and LOXL1 Genotype in PseudoexfoliationPubmed:27116380
- LOX Fails to Substitute for RANKL in Osteoclastogenesis.pubmed:27606829
- Blocking Surgically Induced Lysyl Oxidase Activity Reduces the Risk of Lung Metastases.pubmed:28445728
- Lysyl oxidase is involved in synovial hyperplasia and angiogenesis in rats with collagen‑induced arthritispubmed:28901438
- A Global Assessment of Circulating Prolysyl Oxidase in Nonischemic Patients With Garden-variety Heart Failure With Preserved Ejection FractionPubmed:29807761
- Lysyl oxidase inhibition via β-aminoproprionitrile hampers human umbilical vein endothelial cell angiogenesis and migration in vitroPubmed:29393489
- Lysyl Oxidase is a key player in BRAF/MAPK pathway-driven thyroid cancer aggressivenessPubmed: 30398411
- Lysyl Oxidase Directly Contributes to Extracellular Matrix Production and Fibrosis in Systemic Sclerosis.Pubmed: 33026236
- Collagen Cross©\Linking Is Associated With Cardiac Remodeling in Hypertrophic Obstructive Cardiomyopathy33356379