Multiplex Assay Kit for Motilin (MTL) ,etc. by CBA (Cytometric Bead Array)
MLN; MAP; Promotilin; Motilin-associated peptide
Overview
Properties
- Product No.CMA575Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryEndocrinologyGastroenterologyHormone metabolism
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 83-98 | 88 |
| EDTA plasma(n=5) | 82-94 | 86 |
| heparin plasma(n=5) | 80-89 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 80-89% | 98-105% | 80-105% | 90-99% |
| EDTA plasma(n=5) | 86-105% | 82-103% | 80-94% | 94-101% |
| heparin plasma(n=5) | 93-105% | 87-101% | 89-96% | 86-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:MTL) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) and unlabeled Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Motilin (MTL) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Motilin (MTL) ,etc. by CBA (Cytometric Bead Array) in the sample.
Giveaways
Increment services
Citations
- 清醒状态下热射病大鼠胃肠动力与胃泌素、胃动素的变化Wjgnet:Source
- Using the "target constituent removal combined with bioactivity assay" strategy to investigate the optimum arecoline content in charred areca nut.pubmed:28054652
- Positive enhancement of Lactobacillus fermentum HY01 on intestinal movements of mice having constipation10.1007/s13765-017-0327-3
- Colonic Transit Time and Gut Peptides in Adult Patients with Slow and Normal Colonic Transit Constipationpubmed:29082242
- Home-Based Transcutaneous Neuromodulation Improved Constipation via Modulating Gastrointestinal Hormones and Bile AcidsPubmed:29853946
- The Relations Among Serum Ghrelin, Motilin and Gastric Emptying and Autonomic Function in Autoimmune GastritisPubmed:29753372
- Integrative effects of transcutaneous electrical acustimulation on abdominal pain, gastrointestinal motility, and inflammation in patients with early‐stage acute …34536258
- The Inhibitory Effects of Naringin in a Rat Model of Postoperative Intraperitoneal Adhesion FormationPubmed:35069760
