Multiplex Assay Kit for Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) Mus musculus (Mouse) Protein, Antibody, Assaykit, Service

NTS; NTS1; NmN-125; NN; Tail peptide Neuromedin N

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 669.00 US$ 955.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-93 89
EDTA plasma(n=5) 89-96 93
heparin plasma(n=5) 87-98 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-99% 87-101% 79-96% 93-101%
EDTA plasma(n=5) 84-93% 95-105% 99-105% 79-104%
heparin plasma(n=5) 80-103% 95-104% 82-101% 84-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:NT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) and unlabeled Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Neurotensin (NT) ,etc. by CBA (Cytometric Bead Array) in the sample.

Giveaways

Citations

  • Colonic Transit Time and Gut Peptides in Adult Patients with Slow and Normal Colonic Transit Constipationpubmed:29082242
  • Inhibition of Peroxynitrite-induced mitophagy activation attenuates cerebral ischemia-reperfusion injuryPubmed:29307080
  • Adipose Tissue-Derived Biomarkers of Intestinal Barrier Functions for the Characterization of Diarrhoea-Predominant IBS
  • Functional analysis of gut microbiota and immunoinflammation in children with autism spectrum disordersPubmed: 31320306
  • Association between Circular RNA CDR1as and Post-Infarction Cardiac Function in Pig Ischemic Heart Failure: Influence of the Anti-Fibrotic Natural Compounds …Pubmed: 32823854
  • Qiliqiangxin Improves Cardiac Function through Regulating Energy Metabolism via HIF-1α-Dependent and Independent Mechanisms in Heart Failure Rats …Pubmed: 32626732
  • Identification of U-shaped Curve Relation in Pro-neurotensin and Risk of Coronary Artery Disease (CAD) in Premature CAD Patients
  • Effect of dobutamine on intrinsic myocardial function and myocardial apoptosis in septic rats with myocardial dysfunction
  • Harmine is an effective therapeutic small molecule for the treatment of cardiac hypertrophy33785860
  • Elabela gene therapy promotes angiogenesis after myocardial infarction34291565
  • Renal Impairment Detectors: IGFBP-7 and NGAL as Tubular Injury Markers in Multiple Myeloma Patients34946293

Recommend products