Multiplex Assay Kit for Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) Pan-species (General) Protein, Antibody, Assaykit, Service

Pitocin; Syntocinon

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 543.00 US$ 775.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-104 94
EDTA plasma(n=5) 86-93 89
heparin plasma(n=5) 96-105 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-101% 89-96% 78-93% 87-101%
EDTA plasma(n=5) 80-94% 88-101% 82-90% 93-101%
heparin plasma(n=5) 87-94% 95-103% 78-91% 85-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:OT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) and unlabeled Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) (Standards or samples) with the pre-coated antibody specific to Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Oxytocin (OT) ,etc. by CBA (Cytometric Bead Array) in the sample.

Giveaways

Increment services

Citations

  • Sex-specific associations between plasma oxytocin levels and schizotypal personality features in healthy individualsPubmed:24411593
  • Administration of atosiban in patients with endometriosis undergoing frozen–thawed embryo transfer: a prospective, randomized studyPubmed:27143518
  • Increased oxytocin levels among abstinent heroin addicts: Association with aggressiveness, psychiatric symptoms and perceived childhood neglect.pubmed:28093220
  • Can hypoxia enhance sexual arousal?-Molecular-biological analysis of the hypothalamus in male rats placed with oestrous female rats under hypoxic …files:ijcem0031358.pdf
  • Administration of atosiban in patients with endometriosis undergoing frozen–thawed embryo transfer: a prospective, randomized studypubmed:27143518
  • Intranasal oxytocin reduces provoked symptoms in female patients with posttraumatic stress disorder despite exerting sympathomimetic and positive chronotropic effects in a randomized controlled trial.pubmed:28209155
  • Plasma oxytocin levels in major depressive and bipolar II disorderspubmed:28865715
  • Intranasal oxytocin reduces provoked symptoms in female patients with posttraumatic stress disorder despite exerting sympathomimetic and positive chronotropic effects in a randomized controlled trial10.1186:s12916-017-0801-0
  • The Association between the Level of Plasma Oxytocin and Craving among Former Heroin UsersPubmed:29902803
  • Involvement of Hyperpolarization-Activated Cyclic Nucleotide-Gated Channel 3 in Oxytocin Neuronal Activity in Lactating Rats With Pup DeprivationPubmed: 32962418
  • Effects of transcutaneous electrical nerve stimulation applied at different frequencies during labor on hormone levels, labor pain perception, and anxiety: a randomized …
  • Predicting the Treatment Outcomes of Antidepressants Using a Deep Neural Network of Deep Learning in Drug-Naïve Major Depressive Patients

Recommend products