Multiplex Assay Kit for Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array)
PLA2G7; PAF-AH; PAFAH; Lp-PLA2; LDL-PLA2; Platelet Activating Factor Acetylhydrolase,Plasma; Phospholipase A2,Group VII; LDL-associated phospholipase A2; Phospholipase A2, Lipoprotein Associated
Overview
Properties
- Product No.CMA867Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryEnzyme & KinaseMetabolic pathwayInfection immunity
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 90-98 | 93 |
| EDTA plasma(n=5) | 91-99 | 96 |
| heparin plasma(n=5) | 96-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 92-101% | 92-101% | 87-95% | 86-95% |
| EDTA plasma(n=5) | 97-105% | 87-104% | 78-91% | 86-104% |
| heparin plasma(n=5) | 83-91% | 91-105% | 91-102% | 90-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle
Anti-Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Phospholipase A2 Group VII (LpPLA2) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.
Giveaways
Increment services
Citations
- The effects of different intensity walking programs on serum blood lipids, high-sensitive C-reactive protein, and lipoprotein-associated phospholipase A2 in premenopausal womenScienceDirect: S0765159710000262
- Association of Serum Lipoprotein-Associated Phospholipase A2 Level with Nonalcoholic Fatty Liver DiseaseWiley: source
- Effects of Pycnogenol on endothelial function in patients with stable coronary artery disease: a double-blind, randomized, placebo-controlled, cross-over studyPubMed: 22240497
- Effects of Lipid-Lowering Drugs on Irisin in Human Subjects In Vivo and in Human Skeletal Muscle Cells Ex VivoPubMed: PMC3759413
- Influence of Tongfengtai Granules on Inflammatory Factor in Acute Gouty Arthritis Model RatsSource
- Everolimus therapy is associated with reduced lipoprotein-associated phospholipase A2 (Lp-Pla2) activity and oxidative stress in heart transplant recipients.Pubmed: 23958269
- Lipoprotein-Associated Phospholipase A2 Mass Level Is Increased in Elderly Subjects with Type 2 Diabetes MellitusHindawi: 278063
- The Role of Asymmetric Dimethylarginine and Lipoprotein Associated Phospholipase A2 in Children and Adolescents with DyslipidemiaScirp:Source
- In vitro lipid-lowering and fibrinolytic effects of regulatory leucine-containing glyprolines in human bloodSpringer:Source
- Lipoprotein-associated phospholipase A2 and AGEs are associated with cardiovascular risk factors in women with history of gestational diabetes mellitus.Pubmed:24397392
- Lipoprotein-Associated Phospholipase A 2 Mass Level Is Increased in Elderly Subjects with Type 2 Diabetes MellitusPubmed:24818163
- Effects of sitagliptin therapy on markers of low-grade inflammation and cell adhesion molecules in patients with type 2 diabetesPubmed:25034387
- Effect of Extended‐Release Niacin on High‐Density Lipoprotein (HDL) Functionality, Lipoprotein Metabolism, and Mediators of Vascular Inflammation in Statin‐Treated PatientsPubMed: 26374297
- VEbscohost
- Effect of Pitavastatin Treatment on ApoB-48 and Lp-PLA2 in Patients with Metabolic Syndrome: Substudy of PROspective Comparative Clinical Study Evaluating the Efficacy and Safety of PITavastatin in Patients with Metabolic Syndromepmc:PMC4803547
- Effect of dipyridamole on myocardial reperfusion injury: A double‐blind randomized controlled trial in patients undergoing elective coronary artery bypass surgeryPubmed:25773594
- Effect of intensive insulin treatment on plasma levels of lipoprotein-associated phospholipase A 2 and secretory phospholipase A 2 in patients with newly …articles:10.1186
- SERUM LIPOPROTEIN-ASSOCIATED PHOSPHOLIPASE A2 IN MALES WITH METABOLIC SYNDROME AND OBSTRUCTIVE SLEEP APNEA.jrnl:1841098
- Biomarker for diagnosis of moyamoya disease:
- Circulating fatty-acid binding-protein 4 levels predict CV events in patients after coronary interventionsPubmed: 32859455
- Can admission lipoprotein-associated phospholipase A2 predict the symptomatic cerebral vasospasm following aneurysmal subarachnoid hemorrhage?