Multiplex Assay Kit for Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) Rattus norvegicus (Rat) Protein, Antibody, Assaykit, Service

Pro-Calcitonin

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 575.00 US$ 821.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-98 95
EDTA plasma(n=5) 94-105 99
heparin plasma(n=5) 87-98 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-99% 97-105% 79-102% 91-99%
EDTA plasma(n=5) 96-103% 96-105% 93-101% 82-94%
heparin plasma(n=5) 94-105% 91-105% 82-101% 82-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Procalcitonin (PCT) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Increment services

Citations

  • Evaluation of neutrophilic CD64, interleukin 10 and procalcitonin as diagnostic markers of early- and late-onset neonatal sepsisPubMed: 20085423
  • Effects of Berberine Against Radiation-Induced Intestinal Injury in MicePubMed: 20637981
  • Diagnostic and prognostic value of procalcitonin and phosphorus in acute mesenteric ischemiaPubMed: 21935794
  • Serum procalcitonin and its relation to the outcome of ventilator-associated pneumoniain childrenEssbronchology: Source
  • The Assessment of Vitamin D, Antimicrobial Peptides and Procalcitonin in BronchiectasisWaikato:Source
  • Evaluation of the Diagnostic Utility of Fc Gamma Receptor Type 1 (nCD64) and Procalcitonin in Comparison with Conventional Methods for Diagnosis of Early Onset Neonatal SepsisEjmm:Source
  • Efficacy of measuring procalcitonin levels in determination of prognosis and early diagnosis of bacterial resistance in sepsisPubmed:25657488
  • The use and value of procalcitonin in solid organ transplantationPubMed: 25996831
  • Diagnostic Value of Procalcitonin Levels in Acute Mesenteric IschemiaPubMed: 26185718
  • Macrocalcitonin is a novel pitfall in the routine of serum calcitonin immunoassayPubMed: 26647152
  • Procalcitonin and Pentraxin-3: Current biomarkers in inflammation in white coat hypertensionPubMed: 26040439
  • Variation of Circulating Inflammatory Mediators in Staphylococcus aureus and Escherichia coli BloodstreamInfection.Pubmed:26772168
  • Consistency and pathophysiological characterization of a rat polymicrobial sepsis model via the improved cecal ligation and puncture surgeryPubmed:26802602
  • Early prediction of intestinal mucosal barrier function impairment by elevated serum procalcitonin in rats with severe acute pancreatitis.Pubmed:26804005
  • Risk Factors of Acute Pancreatitis in Oral Double Balloon Enteroscopy.pubmed:27638962
  • Changes in inflammatory mediators as a result of intermittent hypoxia in obstructive sleep apnea syndromepubmed:28960823
  • INTERLEUKIN-1 RECEPTOR 2: A NEW BIOMARKER FOR SEPSIS DIAGNOSIS AND GRAM-NEGATIVE/GRAM-POSITIVE BACTERIAL DIFFERENTIATIONpubmed:27984536
  • Hepatic Macrophages are the Cell Source of Hepatic Procalcitonin in Acute Liver FailurePubmed:29913443
  • Inflammatory mediators in the diagnosis and treatment of acute pancreatitis: pentraxin-3, procalcitonin and myeloperoxidasePubmed:29593801
  • Expression pattern of soluble triggering receptor expressed on myeloid cells-1 in mice with Acinetobacter baumannii colonization and infection in the lungPubmed:29707313
  • Procalcitonin and C-reactive protein as peripheral inflammatory markers in antipsychotic drug-free schizophrenia patientsPubmed:29723719
  • The predictive value of joint detection of serum amyloid protein A, PCT, and Hs-CRP in the diagnosis and efficacy of neonatal septicemia.Pubmed: 31298341
  • Modestly Elevated Serum Procalcitonin Levels in Patients with Rheumatoid Arthritis Free of Active InfectionPubmed: 33080909
  • Reevaluation of Lung Injury in TNF-Induced Shock: The Role of the Acid SphingomyelinasePubmed: 32410851
  • Early label-free analysis of mitochondrial redox states by Raman spectroscopy predicts septic outcomes
  • Moesin Is a Novel Biomarker of Endothelial Injury in Sepsis33628853
  • Circulating nuclear factor-kappa B mediates cancer-associated inflammation in human breast and colon cancer33776564
  • Original contribution: sleeve gastrectomy reduces soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1) levels in patients with morbid obesityPubmed:35044516
  • Procalcitonin is expressed in osteoblasts and limits bone resorption through inhibition of macrophage migration during intermittent PTH treatmentPubmed:35087025

Recommend products