Multiplex Assay Kit for Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) Homo sapiens (Human) Protein, Antibody, Assaykit, Service

Nampt; NAmPRTase; PBEF; PBEF1; Pre-B-Cell Colony Enhancing Factor; Nicotinamide Phosphoribosyltransferase

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 529.00 US$ 756.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 98
EDTA plasma(n=5) 95-104 101
heparin plasma(n=5) 87-99 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 88-102% 81-96% 91-99%
EDTA plasma(n=5) 81-88% 79-97% 85-98% 87-99%
heparin plasma(n=5) 80-95% 86-94% 83-97% 78-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Visfatin (VF) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Visfatin (VF) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • EFFECT OF 8 WEEKS ENDURANCE TRAINING ON PLASMA VISFATIN IN MIDDLE-AGED MENBrjb: source
  • The relationship between visfatin and HOMA-IR in hypertensive patients, and the effect of antihypertensive drugs on visfatin and HOMA-IR in hypertensive patients with insulin resistanceScienceDirect: S0168822711002956
  • Early-effect of bariatric surgery (Scopinaro method) on intestinal hormones and adipokines in insulin resistant Wistar rat.Pubmed: 24304571
  • CTRP3 modulates the expression and secretion of adipokines in 3T3-L1 adipocytesPubmed:25168658
  • Plasma visfatin levels and mRNA expression of visfatin in peripheral blood mononuclear cells and peripheral blood monocyte-derived macrophages from normal weight females with polycystic ovary syndromePubmed:Pmc3991522
  • Visfatin derived from ascites promotes ovarian cancer cell migration through Rho/ROCK signaling-mediated actin polymerization.Pubmed:25055182
  • Visfatin −948G/T and resistin −420C/Gpolymorphisms in Egyptian type 2 diabetic patients with and without cardiovascular diseasesNrcresearchpress:Source
  • Antidiabetic Effect of Galantamine: Novel Effect for a Known Centrally Acting DrugPubMed: 26262991
  • Changes in concentration of visfatin during four weeks of inpatient treatment of alcohol dependent malesScience: Article
  • Variation in blood levels of hormones in obese patients following weight reduction induced by endoscopic and surgical bariatric therapiesPubMed: 26539806
  • Genetic Variations in Visfatin and Resistin Genes in Egyptian Type 2 Diabetic Patients With and Without ComplicationsPubMed: 25120107
  • Favorable outcomes of hydroxychloroquine in insulin resistance may be accomplished by adjustment of the endothelial dysfunction as well as the skewed balance of adipokinesscience:S0065128116301234
  • Changes in Serum Nampt Levels and Its Significances in Diabetic Nephropathy Patients-The Potential Role of Nampt in T2DM with Diabetic Nephropathy.pubmed:28699485
  • Post-chemotherapy serum anti-müllerian hormone level predicts ovarian function recoveryPubmed:30012648
  • Effect of maternal hypothyroidism during pregnancy on insulin resistance, lipid accumulation and mitochondrial dysfunction in skeletal muscle of fetal ratsPubmed:29784871
  • Hyperinsulinemic-euglycemic clamp over the first year of use of depot-medroxyprogesterone acetate as a contraceptivePubmed:29665358
  • Analysis of synovial fluid visfatin level in temporomandibular joint disordersPubmed:29385907
  • Resistin and visfatin concentrations are related to central obesity and inflammation in Brazilian children10.1186:s41110-018-0060-7
  • Transcriptional Regulation of NAMPT Gene by Glycogen Synthase Kinase 3β in Goat AdipocytesPubmed: 30615481
  • The Effect of 8 Weeks Aquatic Exercise Program on Plasma Visfatin Level and Some Blood Factors in Obese Men
  • Adipokines as Biomarkers in Health and Disease
  • Plasma concentration and expression of adipokines in epicardial and subcutaneous adipose tissue are associated with impaired left ventricular filling patternPubmed: 31533725
  • Relationshıp of spontaneous subarachnoid haemorrhage and cerebral aneurysm to serum Visfatin and Nesfatin-1 levelsPubmed: 32311618
  • Effects of 10-Week Concurrent Training on Insulin Resistance and the Serum Levels of Vaspin and Visfatin in Overweight Females
  • Different Ratios of Corn and Coconut Oil Blends in High©\Fat Diets Influence Fat Deposition without Altering Metabolic Biomarkers in Male Rats

Recommend products