Multiplex Assay Kit for Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) Homo sapiens (Human) Protein, Antibody, Assaykit, Service

XO; XOR; XOD; Xanthine Oxidase; NAD+-Xanthine Dehydrogenase; Xanthine-NAD+ Oxidoreductase; Xanthine/NAD+ Oxidoreductase; Xanthine Oxidoreductase

  • UOM
    1. 48T
    2. 96T
  • FOB US$ 588.00 US$ 840.00
  • Quantity
Add to Cart Distributors
Overview
Properties
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • Multiplex Assay Kit for Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Multiplex Assay Kit for Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Recovery

Matrices listed below were spiked with certain level of recombinant Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-101 89
EDTA plasma(n=5) 95-102 98
heparin plasma(n=5) 78-99 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-105% 93-104% 79-101% 89-97%
EDTA plasma(n=5) 86-96% 80-93% 91-98% 80-94%
heparin plasma(n=5) 85-94% 98-105% 82-91% 97-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Multiplex Assay Kit for Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array)

Test principle

Anti-Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Xanthine Dehydrogenase (XDH) ,etc. by CBA (Cytometric Bead Array) in the sample and corresponding value of MFI (Median Fluorescence Intensity). Flow Cytometer was used to determine and calculate the sample concentration.

Giveaways

Citations

  • Glutathione S-Transferase P1 Correlated with Oxidative Stress in Hepatocellular CarcinomaPubMed: PMC3619117
  • Resveratrol ameliorates oxidative stress and inhibits aquaporin 4 expression following rat cerebral ischemia-reperfusion injuryPubMed: 26458999
  • Set-up and application of an analytical approach for the quality control of purified colostrum as food supplementPubmed:27341426
  • Circulating cell-free DNA of methylated insulin-like growth factor-binding protein 7 predicts a poor prognosis in hepatitis B virus-associated hepatocellular carcinoma …Pubmed:29463155

Recommend products