Multiplex Assay Kit for Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay)
SCGB1A1; CC10; CCSP; UGB; UG; Uteroglobin; Uteroglobin; Urinary Protein 1; Clara Cell Secretory Protein; Secretoglobin Family 1A Member 1; Clara-Cell Specific 10-kD Protein
(Note: Up to 8-plex in one testing reaction)
- UOM
- FOB US$ 405.00 US$ 420.00 US$ 443.00 US$ 475.00 US$ 506.00 US$ 552.00 US$ 622.00 US$ 778.00
- Quantity
Overview
Properties
- Product No.LMA857Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- ApplicationsFLIA Kit for Antigen Detection.
Research use only - DownloadInstruction Manual
- CategoryInfection immunityCardiovascular biologyPulmonology
Sign into your account
Share a new citation as an author
Upload your experimental result
Review

Contact us
Please fill in the blank.
Recovery
Matrices listed below were spiked with certain level of recombinant Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-104 | 89 |
EDTA plasma(n=5) | 97-105 | 101 |
heparin plasma(n=5) | 86-101 | 89 |
sodium citrate plasma(n=5) | 82-96 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Clara Cell Protein 16 (CC16) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-101% | 83-97% | 81-94% | 82-92% |
EDTA plasma(n=5) | 85-101% | 96-104% | 97-105% | 88-97% |
heparin plasma(n=5) | 78-96% | 88-105% | 78-101% | 94-103% |
sodium citrate plasma(n=5) | 86-98% | 91-99% | 80-91% | 78-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:CC16) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.
Giveaways
Increment services
Citations
- Pulmonary functions and blood biochemical markers for workers with and without coal worker pneumoconiosisSciencepub: Source
- Analysis of the Protective Biochemical and Pathologic Effects of Aminoguanidine on an Experimental Aspiration Pneumonitis Model Induced by Bile AcidsPubMed: S0011393X12000562
- Effects of leflunomide on inflamation and fibrosis in bleomycine induced pulmonary fibrosis in wistar albino ratsPubmed: 24255778
- The therapeutic effects of anti-oxidant and anti-inflammatory drug quercetin on aspiration-induced lung injury in ratsPubmed: 24122261
- The effects of α-tocopherol on oxidative damage and serum levels of Clara cell protein 16 in aspiration pneumonitis induced by bile acidsPubmed: 23023024
- The evaluation of different treatment protocols for trauma-induced lung injury in ratsPubmed: 24605218
- Susceptibility to COPD: Differential Proteomic Profiling after Acute SmokingPubmed:25036363
- Urine proteome analysis by C18 plate–matrix-assisted laser desorption/ionization time-of-flight mass spectrometry allows noninvasive differential diagnosis …Pubmed:30024955
- N-Acetylcysteine inhalation improves pulmonary function in patients received Liver Transplantation.Doi: 10.1042/BSR20180858
- Mechanical activation of TRPV4 channels controls albumin reabsorption by proximal tubule cells.
- An ultrasensitive electrochemical detection of tryptase using 3D macroporous reduced graphene oxide nanocomposites by one-pot electrochemical synthesis
- Effects of mammary nutrient demand on glucose kinetics of dairy cows in early lactation
- Role of bone marrow-derived mesenchymal stem cells in alleviating pulmonary epithelium damage and extracellular matrix remodeling in a rat model of lung fibrosis …Pubmed: 32909452
- The Protective Effects of Butorphanol on Pulmonary Function of Patients with Obesity Undergoing Laparoscopic Bariatric Surgery: a Double-Blind Randomized …Pubmed: 32535786
- Elevated plasma levels of epithelial and endothelial cell markers in COVID-19 survivors with reduced lung diffusing capacity six months after hospital …Pubmed:35189887
- Lung-Protective Effects of Lidocaine Infusion on Patients with Intermediate/High Risk of Postoperative Pulmonary Complications: A Double-Blind Randomized …Pubmed:35422611