ELISA Kit DIY Materials for Cartilage Oligomeric Matrix Protein (COMP) Rattus norvegicus (Rat) Assay Kit DIY Materials

MED; EDM1; EPD1; PSACH; THBS5; TSP-5; Pseudoachondroplasia,Epiphyseal Dysplasia 1,Multiple; Thrombospondin 5

Add to Cart Distributors
Overview
Properties
  • Reagent Contents Capture Antibody, Detection Antibody, Standard, Streptavidin-HRP, TMB Substrate, 96-well Plate
  • Detectable SampleSerum, plasma and other biological fluids.
  • Applicable PrincipleDouble-antibody Sandwich ELISA for Antigen Detection
  • Detectable Range3.12-200ng/mL
  • Applicable Sensitivity1.37ng/mL
Share your citation Upload your experimental result Review Leave a message
Loading...

Share a new citation as an author

Upload your experimental result

Review

Please attach serial No. on instruction manual

Contact us

Please fill in the blank.

Name*
Organization
Address
E-mail address*
Telephone
Inquiry*
Verification code* CheckCode
  • ELISA Kit DIY Materials for Cartilage Oligomeric Matrix Protein (COMP) Packages (Simulation)
  • ELISA Kit DIY Materials for Cartilage Oligomeric Matrix Protein (COMP) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specifity

The Abs in the kit have high sensitivity and excellent specificity for detection of Cartilage Oligomeric Matrix Protein (COMP). No significant cross-reactivity or interference between Cartilage Oligomeric Matrix Protein (COMP) and analogues was observed.

Usage

1. Coat the plates with 100μL per well of working solution of Capture Antibody.incubate overnight at 4°C or incubate at 37°C for 2 hours.
2. Aspirate and wash 1 time.
3. Block the plates with 200 μL per well of working solution of Blocking Buffer. Incubate at 37°C for 1.5 hours.
4. Aspirate and wash 1 time. The plates are now ready for sample detection, the protocol is the same as regular ELISA.

Storage

Antibodies, Standard and Streptavidin-HRP should be stored at -20°C. TMB should be stored at 4°C. 96-well Plate could be stored at room temperature. The contents are valid for twelve months. They are stable for one month after opening when stored at 4°C.

Support pack

Citations

  • Genetic analysis and serum level of cartilage oligomeric matrix protein in patients with pseudoachondroplasia CMJ: 201082337960590
  • Decreased Plasma COMP and Increased Plasma CTX-II Levels in a Chinese Pseudoachondroplasia Family with Novel COMP Mutationpubmed:29104872
  • Mori Folium water extract alleviates articular cartilage damages and inflammatory responses in monosodium iodoacetate‑induced osteoarthritis ratspubmed:29067461
  • Cartilage Oligomeric Matrix Protein Levels in Synovial Fluid in Patients With Primary Knee Osteoarthritis And Healthy Controls: A Preliminary Comparative Analysis With Serum Cartilage Oligomeric Matrix Proteindoi: 10.5606/ArchRheumatol.2017.6220
  • Cartilage Oligomeric Matrix Protein Levels in Type 2 Diabetes Associated with Primary Knee Osteoarthritis PatientsPubmed: 30526057
  • The relationship between the serum and synovial fluid osteopontin (OPN), cartilage oligomeric matrix protein (COMP), and the severity of knee osteoarthritis …
  • Diagnostic Accuracy of Cartilage Oligomeric Matrix Protein (COMP), for Cartilage Damage in Rheumatoid Arthritis

Recommend products